Right heart catheterization

Revision as of 15:44, 20 August 2012 by WikiBot (talk | contribs) (Robot: Automated text replacement (-{{SIB}} +, -{{EH}} +, -{{EJ}} +, -{{Editor Help}} +, -{{Editor Join}} +))
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

WikiDoc Resources for Right heart catheterization

Articles

Most recent articles on Right heart catheterization

Most cited articles on Right heart catheterization

Review articles on Right heart catheterization

Articles on Right heart catheterization in N Eng J Med, Lancet, BMJ

Media

Powerpoint slides on Right heart catheterization

Images of Right heart catheterization

Photos of Right heart catheterization

Podcasts & MP3s on Right heart catheterization

Videos on Right heart catheterization

Evidence Based Medicine

Cochrane Collaboration on Right heart catheterization

Bandolier on Right heart catheterization

TRIP on Right heart catheterization

Clinical Trials

Ongoing Trials on Right heart catheterization at Clinical Trials.gov

Trial results on Right heart catheterization

Clinical Trials on Right heart catheterization at Google

Guidelines / Policies / Govt

US National Guidelines Clearinghouse on Right heart catheterization

NICE Guidance on Right heart catheterization

NHS PRODIGY Guidance

FDA on Right heart catheterization

CDC on Right heart catheterization

Books

Books on Right heart catheterization

News

Right heart catheterization in the news

Be alerted to news on Right heart catheterization

News trends on Right heart catheterization

Commentary

Blogs on Right heart catheterization

Definitions

Definitions of Right heart catheterization

Patient Resources / Community

Patient resources on Right heart catheterization

Discussion groups on Right heart catheterization

Patient Handouts on Right heart catheterization

Directions to Hospitals Treating Right heart catheterization

Risk calculators and risk factors for Right heart catheterization

Healthcare Provider Resources

Symptoms of Right heart catheterization

Causes & Risk Factors for Right heart catheterization

Diagnostic studies for Right heart catheterization

Treatment of Right heart catheterization

Continuing Medical Education (CME)

CME Programs on Right heart catheterization

International

Right heart catheterization en Espanol

Right heart catheterization en Francais

Business

Right heart catheterization in the Marketplace

Patents on Right heart catheterization

Experimental / Informatics

List of terms related to Right heart catheterization

Cardiology Network

Discuss Right heart catheterization further in the WikiDoc Cardiology Network
Adult Congenital
Biomarkers
Cardiac Rehabilitation
Congestive Heart Failure
CT Angiography
Echocardiography
Electrophysiology
Cardiology General
Genetics
Health Economics
Hypertension
Interventional Cardiology
MRI
Nuclear Cardiology
Peripheral Arterial Disease
Prevention
Public Policy
Pulmonary Embolism
Stable Angina
Valvular Heart Disease
Vascular Medicine

Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]


Overview

Synonyms include: Pulmonary artery catheterization, wedge, PA line, Swan Ganz catheterization, right heart cath.

Pulmonary artery catheterization is the insertion of a catheter into a pulmonary artery. Its purpose is diagnostic; it is used to detect heart failure or sepsis, monitor therapy, and evaluate the effects of drugs. The pulmonary artery catheter allows direct, simultaneous measurement of pressures in the right atrium, right ventricle, pulmonary artery, and the filling pressure ("wedge" pressure) of the left atrium.

The pulmonary artery catheter is frequently referred to as a Swan-Ganz catheter, in honor of its inventors Jeremy Swan and William Ganz, from Cedars-Sinai Medical Center. The idea for this catheter (as later revealed by Dr. Swan) came about from the observation of sailboats on the water.

Indications

General indications are

  • Assessment of type of shock
  • Assessment of response to therapy
  • Management of postoperative open heart surgical patients
  • Assessment of cardiac tamponade / constriction

Procedure

The catheter is introduced through a large vein—often the internal jugular, subclavian, or femoral veins. From this entry site, it is threaded, often with the aid of fluoroscopy, through the right atrium of the heart, the right ventricle, and subsequently into the pulmonary artery.

The standard pulmonary artery catheter is equipped with an inflatable balloon at the tip, which facilitates its placement into the pulmonary artery through the flow of blood. The balloon, when inflated, causes the catheter to "wedge" in a small pulmonary blood vessel. So wedged, the catheter can provide a measurement of the pressure in the left atrium of the heart.

Complications

The procedure is not without risk, and complications can be life threatening. It can lead to arrhythmias, rupture of the pulmonary artery, thrombosis, infection, pneumothorax, bleeding, and other problems.

Controversy

The benefit of the use of this type of catheter has been controversial. Therefore many clinicians minimize its use.

Evidence of benefit

Several studies in the 1980s seemed to show a benefit of the increase in physiological information. Many reports showing benefit of the PA catheter are from anesthestic and surgical settings. In these settings cardiovascular performance was optimized thinking patients would have supranormal metabolic requirements.

Evidence of harm or lack of benefit

Contrary to earlier studies there is growing evidence the use of a PA catheter (PAC) does not necessarily lead to improved outcome. For example, see [2]. The following explanations have been advanced. One explanation could be that nurses and physicians were insufficiently knowledgeable to adequately interpret the PA catheter measurements. Also, the benefits might be reduced by the complications from the use of the PAC. Furthermore, using information from the PAC might result in a more aggressive therapy causing the detrimental effect. Or, it could give rise to more harmful therapies (i.e. achieving supranormal values could be associated with increased mortality).

References

  • Swan HJ, Ganz W, Forrester J, Marcus H, Diamond G, Chonette D. Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter. N Engl J Med 1970;283:447-51. PMID 5434111.