Meropenem microbiology

Jump to navigation Jump to search


Meropenem
MERREM® FDA Package Insert
Description
Clinical Pharmacology
Microbiology
Indications and Usage
Contraindications
Warnings
Precautions
Adverse Reactions
Overdosage
Clinical Studies
Dosage and Administration
Compatibility, Reconstitution, and Stability
How Supplied
Labels and Packages

Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]

Microbiology

Meropenem is a broad-spectrum Carbapenem antibiotic. It is active against Gram-positive and Gram-negative bacteria. The bactericidal activity of meropenem results from the inhibition of cell wall synthesis. Meropenem readily penetrates the cell wall of most Gram-positive and Gram-negative bacteria to reach penicillin-binding-protein (PBP) targets. Its strongest affinities are toward PBPs 2, 3 and 4 of Escherichia coli and [[Pseudomonas aeruginosa]]; and PBPs 1, 2 and 4 of Staphylococcus aureus. Bactericidal concentrations (defined as a 3 log10 reduction in cell counts within 12 to 24 hours) are typically 1-2 times the bacteriostatic concentrations of meropenem, with the exception of Listeria monocytogenes against which lethal activity is not observed. Meropenem has significant stability to hydrolysis by β-lactamases of most categories, both penicillinases and cephalosporinases produced by Gram-positive and Gram-negative bacteria. Meropenem should not be used to treat methicillin-resistant staphylococci (MRSA). In vitro tests show meropenem to act synergistically with aminoglycoside antibiotics against some isolates of Pseudomonas aeruginosa.

Lists of Microorganisms

Meropenem has been shown to be active against most isolates of the following microorganisms, both in vitro and in clinical infections as described in the INDICATIONS AND USAGE section.

'Aerobic and facultative Gram-positive microorganisms '

only)

NOTE: Penicillin-resistant isolates had meropenem MIC90 values of 1 or 2 µg/mL, which is above the 0.12 µg/mL susceptible breakpoint for this species.

Aerobic and facultative Gram-negative microorganisms

[[[anaerobic]]] microorganisms

The following in vitro data are available, but their clinical significance is unknown.

At least 90% of the following microorganisms exhibit an in vitro minimum inhibitory concentration (MIC) less than or equal to the susceptible breakpoints for meropenem. However, the safety and effectiveness of meropenem in treating clinical infections due to these microorganisms have not been established in adequate and well-controlled trials.

Aerobic and facultative Gram-positive microorganisms

isolates only).

Aerobic and facultative Gram-negative microorganisms

(β-lactamase and non-β-lactamase-producing isolates)

(ampicillin-resistant, non-β-lactamase-producing isolates[BLNAR isolates])


anaerobic microorganisms

SUSCEPTIBILITY TEST METHODS

When available, the clinical microbiology laboratory should provide cumulative results of in vitro susceptibility test results for antimicrobial drugs used in local hospitals and practice areas to the physician as periodic reports that describe the susceptibility profile of nosocomial and community- acquired pathogens. These reports should aid the physician in selecting the most effective antimicrobial.

Dilution techniques: Quantitative methods are used to determine antimicrobial minimum inhibitory concentrations (MICs). These MICs provide estimates of the susceptibility of bacteria to antimicrobial compounds. The MICs should be determined using a standardized procedure. Standardized procedures are based on a dilution method1,3 (broth or agar) or equivalent with standardized inoculum concentrations and standardized concentrations of meropenem powder. The MIC values should be interpreted according to the criteria provided in Table below.

Diffusion techniques: Quantitative methods that require measurement of zone diameters also provide reproducible estimates of the susceptibility of bacteria to antimicrobial compounds. One such standardized procedure requires the use of standardized inoculum concentrations. This procedure uses paper disks impregnated with 10-µg of meropenem to test the susceptibility of microorganisms to meropenem. The disk diffusion interpretive criteria are provided in Table below. Streptococcus pneumoniae isolates should be tested using 1-µg/mL oxacillin disk. Isolates with oxacillin zone sizes of ≥ 20 mm are susceptible (MIC ≤ 0.06 µg/mL) to penicillin and can be considered susceptible to meropenem for approved indications, and meropenem need not be tested. A meropenem MIC should be determined on isolates of S. pneumoniae with oxacillin zone sizes of ≤19 mm. The disk test does not distinguish penicillin intermediate isolates (i.e., MICs = 0.12-1.0 µg/mL) from isolates that are penicillin resistant (i.e., MICs ≥ 2 µg/mL). Viridans group streptococci should be tested for meropenem susceptibility using an MIC method. Reliable disk diffusion tests for meropenem do not yet exist for testing streptococci.

anaerobic techniques: For [[anaerobic]] bacteria, the susceptibility to meropenem as MICs can be determined by standardized test methods.The MIC values obtained should be interpreted according to the criteria provided in Table below.

No interpretative criteria have been established for testing enterococci and Neisseria meningitidis.

A report of Susceptible indicates that the antimicrobial is likely to inhibit growth of the pathogen if the antimicrobial compound in the blood reaches the concentrations usually achievable. A report of Intermediate indicates that the result should be considered equivocal, and, if the microorganism is not fully susceptible to alternative, clinically feasible drugs, the test should be repeated. This category implies possible clinical applicability in body sites where the drug is physiologically concentrated or in situations where a high dosage of drug can be used. This category also provides a buffer zone that prevents small uncontrolled technical factors from causing major discrepancies in interpretation. A report of Resistant indicates that the antimicrobial is not likely to inhibit growth of the pathogen if the ntimicrobial compound in the blood reaches the concentrations usually achievable; other therapy should be selected.

Quality control: Standardized susceptibility test procedures require the use of quality control microorganisms to control the technical aspects of the test procedures. Standard meropenem powder should provide the following range of values noted in Table below.

[1]

References

  1. "http://www.accessdata.fda.gov/drugsatfda_docs/label/2008/050706s022lbl.pdf" (PDF). External link in |title= (help)

Adapted from the FDA Package Insert.