Coombs test

(Redirected from Coomb's test)
Jump to navigation Jump to search

WikiDoc Resources for Coombs test

Articles

Most recent articles on Coombs test

Most cited articles on Coombs test

Review articles on Coombs test

Articles on Coombs test in N Eng J Med, Lancet, BMJ

Media

Powerpoint slides on Coombs test

Images of Coombs test

Photos of Coombs test

Podcasts & MP3s on Coombs test

Videos on Coombs test

Evidence Based Medicine

Cochrane Collaboration on Coombs test

Bandolier on Coombs test

TRIP on Coombs test

Clinical Trials

Ongoing Trials on Coombs test at Clinical Trials.gov

Trial results on Coombs test

Clinical Trials on Coombs test at Google

Guidelines / Policies / Govt

US National Guidelines Clearinghouse on Coombs test

NICE Guidance on Coombs test

NHS PRODIGY Guidance

FDA on Coombs test

CDC on Coombs test

Books

Books on Coombs test

News

Coombs test in the news

Be alerted to news on Coombs test

News trends on Coombs test

Commentary

Blogs on Coombs test

Definitions

Definitions of Coombs test

Patient Resources / Community

Patient resources on Coombs test

Discussion groups on Coombs test

Patient Handouts on Coombs test

Directions to Hospitals Treating Coombs test

Risk calculators and risk factors for Coombs test

Healthcare Provider Resources

Symptoms of Coombs test

Causes & Risk Factors for Coombs test

Diagnostic studies for Coombs test

Treatment of Coombs test

Continuing Medical Education (CME)

CME Programs on Coombs test

International

Coombs test en Espanol

Coombs test en Francais

Business

Coombs test in the Marketplace

Patents on Coombs test

Experimental / Informatics

List of terms related to Coombs test

For the WikiPatient page for this topic, click here

Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]


Overview

Schematic showing the direct and indirect Coombs tests.

Coombs test (also known as Coombs' test, antiglobulin test or AGT) refers to two clinical blood tests used in immunohematology and immunology.

The two Coombs tests are:

  • Direct Coombs test (also known as direct antiglobulin test or DAT).
  • Indirect Coombs test (also known as indirect antiglobulin test or IAT).

The direct Coombs test is used to detect red blood cells sensitized with igG alloantibody, IgG autoantibody, and complement proteins. It detects antibodies bound to the surface of red blood cells in vivo. The red blood cells (RBCs) are washed (removing the patient's own plasma) and then incubated with antihuman globulin (also known as "Coombs reagent"). If this produces agglutination of the RBCs, the direct Coombs test is positive.

The indirect Coombs test is used in prenatal testing of pregnant women, and in testing blood prior to a blood transfusion. It detects antibodies against RBCs that are present unbound in the patient's serum. In this case, serum is extracted from the blood, and the serum is incubated with RBCs of known antigenicity. If agglutination occurs, the indirect Coombs test is positive.[1]



Mechanism

The two Coombs tests are based on the fact that anti-human antibodies, which are produced by immunizing non-human species with human serum, will bind to human antibodies, commonly IgG or IgM. Animal anti-human antibodies will also bind to human antibodies that may be fixed onto antigens on the surface of red blood cells (also referred to as RBCs), and in the appropriate test tube conditions this can lead to agglutination of RBCs. The phenomenon of agglutination of RBCs is important here, because the resulting clumping of RBCs can be visualised; when clumping is seen the test is positive and when clumping is not seen the test is negative.

Common clinical uses of the Coombs test include the preparation of blood for transfusion in cross-matching, screening for atypical antibodies in the blood plasma of pregnant women as part of antenatal care, and detection of antibodies for the diagnosis of immune-mediated haemolytic anaemias.

Coombs tests are done on serum from venous blood samples which are taken from patients by venipuncture. The venous blood is taken to a laboratory (or blood bank), where trained scientific technical staff do the Coombs tests. The clinical significance of the result is assessed by the physician who requested the Coombs test, perhaps with assistance from a laboratory-based hematologist.

Direct Coombs Test

The direct Coombs test (also known as the direct antiglobulin test or DAT) is used to detect if antibodies or complement system factors have bound to RBC surface antigens in vivo. The DAT is not currently required for pre-transfusion testing but may be included by some laboratories.

Examples of diseases that give a positive direct Coombs test

The direct Coombs test is used clinically when immune-mediated hemolytic anemia (antibody-mediated destruction of RBCs) is suspected. A positive Coombs test indicates that an immune mechanism is attacking the patient's own RBC's. This mechanism could be autoimmunity, alloimmunity or a drug-induced immune-mediated mechanism.

Examples of alloimmune hemolysis

Examples of autoimmune hemolysis

Drug-induced immune-mediated haemolysis

(A memory device to remember that the DAT tests the RBCs and is used to test infants for haemolytic disease of the newborn is:
Rh Disease; R = RBCs, D = DAT.)

Laboratory method

The patient's red blood cells (RBCs) are washed (removing the patient's own serum) and then incubated with antihuman globulin (also known as Coombs reagent). If immunoglobulin or complement factors have been fixed on to the RBC surface in-vivo, the antihuman globulin will agglutinate the RBCs and the direct Coombs test will be positive. (A visual representation of a positive direct Coombs test is shown in the upper half of the schematic).

Indirect Coombs test

The indirect Coombs test (also known as the indirect antiglobulin test or IAT) is used to detect in-vitro antibody-antigen reactions. It is used to detect very low concentrations of antibodies present in a patient's plasma/serum prior to a blood transfusion. In antenatal care, the IAT is used to screen pregnant women for antibodies that may cause hemolytic disease of the newborn. The IAT can also be used for compatibility testing, antibody identification, RBC phenotyping, and titration studies.

Examples of clinical uses of the indirect Coombs test

Blood transfusion preparation

The indirect Coombs test is used to screen for antibodies in the preparation of blood for blood transfusion. The donor's and recipient's blood must be ABO and Rhesus D compatible. Donor blood for transfusion is also screened for infections in separate processes.

  • Antibody screening

A blood sample from the recipient and a blood sample from every unit of donor blood are screened for antibodies with the indirect Coombs test. Each sample is incubated against a wide range of RBCs that together exhibit a full range of surface antigens (ie blood types).

  • Cross matching

The indirect Coombs test is used to test a sample of the recipient's serum against a sample of the blood donor's RBCs. This is sometimes called cross-matching blood.

Antenatal antibody screening

The indirect Coombs test is used to screen pregnant women for IgG antibodies that are likely to pass through the placenta into the foetal blood and cause haemolytic disease of the newborn.

Laboratory method

The IAT is a two-stage test. (A cross match is shown visually in the lower half of the schematic as an example of an indirect Coombs test).

First stage

Washed test red blood cells (RBCs) are incubated with a test serum. If the serum contains antibodies to antigens on the RBC surface, the antibodies will bind onto the surface of the RBCs.

Second stage

The RBCs are washed three or four times with isotonic saline and then incubated with antihuman globulin. If antibodies have bound to RBC surface antigens in the first stage, RBCs will agglutinate when incubated with the antihuman globulin (also known Coombs reagent) in this stage, and the indirect Coombs test will be positive.

Titrations

By diluting a serum containing antibodies the quantity of the antibody in the serum can be gauged. This is done by using doubling dilutions of the serum and finding the maximum dilution of test serum that is able to produce agglutination of relevant RBCs.

Coombs reagent

Coombs reagent (also known as Coombs antiglobulin or antihuman globulin) is used in both the direct Coombs test and the indirect Coombs test. Coombs reagent is antihuman globulin. It is made by injecting human globulin into animals. Coombs reagent contains animal antibodies specific for human immunoglobulins and human complement system factors. More specific Coombs reagents or monoclonal antibodies can be used.

Enhancement Media

Both IgM and IgG antibodies react strongly with their antigens. IgG antibodies are most reactive at 37°C. IgM antibodies are easily detected in saline at room temperature as IgM antibodies are able to bridge between RBC’s owing to their large size, efficiently creating what is seen as agglutination. IgG antibodies are smaller and require assistance to bridge well enough to form a visual agglutination reaction. Reagents used to enhance IgG detection are referred to as potentiators. RBCs have a net negative charge called zeta potential which causes them to have a natural repulsion for one another. Potentiators reduce the zeta potential of RBC membranes. Common potentiators include low ionic strength solution (LISS), albumin, polyethylene glycol (PEG), and proteolytic enzymes.

History of the Coombs test

The Coombs test was first described in 1945 by Cambridge immunologists Robin Coombs (after whom it is named), Arthur Mourant and Rob Race.[2] Historically, it was done in test tubes. Today, it is commonly done using microarray and gel technology.

References

  1. F. Rosen and R. Geha, Case Studies in Immunology, 4th ed., Garland Science, p.173.
  2. Coombs RRA, Mourant AE, Race RR. A new test for the detection of weak and "incomplete" Rh agglutinins. Brit J Exp Path 1945;26:255-66.

External links


de:Antikörpersuchtest fi:Ristikoe


Template:WikiDoc Sources