Wolff-Parkinson-White syndrome pathophysiology: Difference between revisions

Jump to navigation Jump to search
(Created page with " {{Wolff-Parkinson-White syndrome}} {{CMG}}; '''Associate Editor-In-Chief:''' {{CZ}} ==Overview== In normal individuals, electrical activity in the heart is initiated in the ...")
 
No edit summary
Line 1: Line 1:
{{Wolff-Parkinson-White syndrome}}
{{Wolff-Parkinson-White syndrome}}
{{CMG}}; '''Associate Editor-In-Chief:''' {{CZ}}
{{CMG}}; '''Associate Editor-In-Chief:''' {{CZ}}
Line 9: Line 7:


Individuals with WPW syndrome have an accessory pathway that connects the atria and the ventricles, in addition to the AV node.  This accessory pathway is known as the '''[[bundle of Kent]]'''.  This accessory pathway does not share the rate-slowing properties of the AV node, and may conduct electrical activity at a significantly higher rate than the AV node.  For instance, in the example above, if an individual had an atrial rate of 300 beats per minute, the accessory bundle may conduct all the electrical impulses from the atria to the ventricles, causing the ventricles to activate at 300 beats per minute. Extremely fast heart rates are potentially dangerous, and can cause hemodynamic instability. In some cases, the combination of an accessory pathway and cardiac arrhythmias can trigger ventricular fibrillation, a leading cause of [[sudden cardiac death]].
Individuals with WPW syndrome have an accessory pathway that connects the atria and the ventricles, in addition to the AV node.  This accessory pathway is known as the '''[[bundle of Kent]]'''.  This accessory pathway does not share the rate-slowing properties of the AV node, and may conduct electrical activity at a significantly higher rate than the AV node.  For instance, in the example above, if an individual had an atrial rate of 300 beats per minute, the accessory bundle may conduct all the electrical impulses from the atria to the ventricles, causing the ventricles to activate at 300 beats per minute. Extremely fast heart rates are potentially dangerous, and can cause hemodynamic instability. In some cases, the combination of an accessory pathway and cardiac arrhythmias can trigger ventricular fibrillation, a leading cause of [[sudden cardiac death]].


==References==
==References==

Revision as of 02:58, 16 May 2012

Wolff-Parkinson-White syndrome Microchapters

Home

Patient Information

Overview

Historical Perspective

Classification

Pathophysiology

Differentiating Wolff-Parkinson-White syndrome from other Diseases

Epidemiology and Demographics

Risk Factors

Natural History, Complications and Prognosis

Diagnosis

Approach

History and Symptoms

Electrocardiogram

EKG Examples

Other Diagnostic Studies

Treatment

Risk Stratification

Cardioversion

Medical Therapy

Catheter Ablation

Prophylaxis

Consensus Statement

Case Studies

Case #1

Wolff-Parkinson-White syndrome pathophysiology On the Web

Most recent articles

Most cited articles

Review articles

CME Programs

Powerpoint slides

Images

Ongoing Trials at Clinical Trials.gov

US National Guidelines Clearinghouse

NICE Guidance

FDA on Wolff-Parkinson-White syndrome pathophysiology

CDC onWolff-Parkinson-White syndrome pathophysiology

Wolff-Parkinson-White syndrome pathophysiology in the news

Blogs on Wolff-Parkinson-White syndrome pathophysiology

Directions to Hospitals Treating Deep vein thrombosis

Risk calculators and risk factors for Wolff-Parkinson-White syndrome pathophysiology

Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]; Associate Editor-In-Chief: Cafer Zorkun, M.D., Ph.D. [2]

Overview

In normal individuals, electrical activity in the heart is initiated in the sinoatrial (SA) node (located in the right atrium), propagates to the atrioventricular (AV) node, and then through the bundle of His to the ventricles of the heart. (Seeelectrical conduction system of the heart).

The AV node acts as a gatekeeper, limiting the electrical activity that reaches the ventricles of the heart. This function of the AV node is important, because if the signals generated in the atria of the heart were to increase in rate (as they do during atrial fibrillation or atrial flutter), the AV node will limit the electrical activity that conducts to the ventricles. For instance, if the atria are electrically activated at 300 beats per minute, half those electrical impulses are blocked by the AV node, so that the ventricles are activated at 150 beats per minute (giving a pulse of 150 beats per minute). Another important property of the AV node is that it slows down individual electrical impulses. This is manifest on theECG as the PR interval, the time from activation of the atria (manifest as the P wave) and activation of the ventricles (manifest as the QRS complex).

Individuals with WPW syndrome have an accessory pathway that connects the atria and the ventricles, in addition to the AV node. This accessory pathway is known as the bundle of Kent. This accessory pathway does not share the rate-slowing properties of the AV node, and may conduct electrical activity at a significantly higher rate than the AV node. For instance, in the example above, if an individual had an atrial rate of 300 beats per minute, the accessory bundle may conduct all the electrical impulses from the atria to the ventricles, causing the ventricles to activate at 300 beats per minute. Extremely fast heart rates are potentially dangerous, and can cause hemodynamic instability. In some cases, the combination of an accessory pathway and cardiac arrhythmias can trigger ventricular fibrillation, a leading cause of sudden cardiac death.

References