Cardiac disease in pregnancy and valvular heart disease

Revision as of 20:47, 11 October 2011 by Akchakra (talk | contribs)
Jump to navigation Jump to search

Cardiac disease in pregnancy Microchapters

Home

Overview

Pathophysiology

Epidemiology and Demographics

Risk Factors

Diagnosis

History and Symptoms

Physical Examination

Electrocardiogram

Exercise Testing

Radiation Exposure

Chest X Ray

Echocardiography

MRI

CT

Catheterization:

Pulmonary artery catheterization
Cardiac catheterization
Cardiac Ablation

Treatment

Cardiovascular Drugs in Pregnancy

Labor and delivery

Resuscitation in Late Pregnancy

Contraindications to pregnancy

Special Scenarios:

I. Pre-existing Cardiac Disease:
Congenital Heart Disease
Repaired Congenital Heart Disease
Pulmonary Hypertension
Rheumatic Heart Disease
Connective Tissue Disorders
II. Valvular Heart Disease:
Mitral Stenosis
Mitral Regurgitation
Aortic Insufficiency
Aortic Stenosis
Mechanical Prosthetic Valves
Tissue Prosthetic Valves
III. Cardiomyopathy:
Dilated Cardiomyopathy
Hypertrophic Cardiomyopathy
Peripartum Cardiomyopathy
IV. Cardiac diseases that may develop During Pregnancy:
Arrhythmias
Acute Myocardial Infarction
Hypertension

Cardiac disease in pregnancy and valvular heart disease On the Web

Most recent articles

Most cited articles

Review articles

CME Programs

Powerpoint slides

Images

American Roentgen Ray Society Images of Cardiac disease in pregnancy and valvular heart disease

All Images
X-rays
Echo & Ultrasound
CT Images
MRI

Ongoing Trials at Clinical Trials.gov

US National Guidelines Clearinghouse

NICE Guidance

FDA on Cardiac disease in pregnancy and valvular heart disease

CDC on Cardiac disease in pregnancy and valvular heart disease

Cardiac disease in pregnancy and valvular heart disease in the news

Blogs on Cardiac disease in pregnancy and valvular heart disease

Directions to Hospitals Treating Cardiac disease in pregnancy

Risk calculators and risk factors for Cardiac disease in pregnancy and valvular heart disease

Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]; Associate Editor-In-Chief: Anjan K. Chakrabarti, M.D. [2]

Overview

As previously mentioned, rheumatic heart disease remains prevalent in developing countries but is less common in Western countries; as a result Western countries see less mitral stenosis complicating pregnancy. Bicuspid aortic stenosis, mitral regurgitation, aortic regurgitation, and prosthetic valves can all be problematic during pregnancy due to physiologic hemodynamic changes.

For a general overview of valvular heart disease, click here.

Specific Issues with Valvular Disease in Pregnancy

Mitral Stenosis

  • Increase in cardiac output coupled with the increase in heart rate shortens the diastolic filling time
  • Tends to exaggerate the mitral valve gradient
  • Patients should have echocardiography prior to proceeding with pregnancy
  • Exercise echocardiography may be warranted
  • Judicious use of diuretics and beta-blockade are appropriate in symptomatic cases
  • Balloon valvuloplasty has been described in symptomatic cases[1]

Mitral Regurgitation

  • Fairly well tolerated in pregnancy
  • The left ventricle tends to dilate as pregnancy progresses, and this may worsen mitral regurgitation
  • Early delivery is sometimes necessary in case of maternal hemodynamic instability

Aortic Insufficiency

  • As with mitral regurgitation, fairly well tolerated
  • Closer monitoring is warranted, early delivery may be necessary

Aortic Stenosis

  • Generally due to bicuspid aortic valve
  • Moderate stenosis may be tolerated in a compliant patient who is monitored closely
  • Aortic root dilation > 4.5cm is a contraindication to pregnancy.
  • Balloon valvuloplasty has been safely performed in a small subset of pregnancy patients with some success, as described by Myerson et al.[2]

Prosthetic Valves and Pregnancy[3]

References

  1. Routray SN, Mishra TK, Swain S, Patnaik UK, Behera M (2004). "Balloon mitral valvuloplasty during pregnancy". Int J Gynaecol Obstet. 85 (1): 18–23. doi:10.1016/j.ijgo.2003.09.005. PMID 15050462.
  2. Myerson SG, Mitchell AR, Ormerod OJ, Banning AP (2005). "What is the role of balloon dilatation for severe aortic stenosis during pregnancy?". J Heart Valve Dis. 14 (2): 147–50. PMID 15792172.
  3. Elkayam U, Singh H, Irani A, Akhter MW (2004). "Anticoagulation in pregnant women with prosthetic heart valves". J Cardiovasc Pharmacol Ther. 9 (2): 107–15. PMID 15309247.


Template:WH Template:WS