Adjuncts for high risk percutaneous coronary intervention

Revision as of 20:44, 8 August 2012 by WikiBot (talk | contribs) (Bot: Automated text replacement (-{{SIB}} + & -{{EH}} + & -{{EJ}} + & -{{Editor Help}} + & -{{Editor Join}} +))
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

WikiDoc Resources for Adjuncts for high risk percutaneous coronary intervention

Articles

Most recent articles on Adjuncts for high risk percutaneous coronary intervention

Most cited articles on Adjuncts for high risk percutaneous coronary intervention

Review articles on Adjuncts for high risk percutaneous coronary intervention

Articles on Adjuncts for high risk percutaneous coronary intervention in N Eng J Med, Lancet, BMJ

Media

Powerpoint slides on Adjuncts for high risk percutaneous coronary intervention

Images of Adjuncts for high risk percutaneous coronary intervention

Photos of Adjuncts for high risk percutaneous coronary intervention

Podcasts & MP3s on Adjuncts for high risk percutaneous coronary intervention

Videos on Adjuncts for high risk percutaneous coronary intervention

Evidence Based Medicine

Cochrane Collaboration on Adjuncts for high risk percutaneous coronary intervention

Bandolier on Adjuncts for high risk percutaneous coronary intervention

TRIP on Adjuncts for high risk percutaneous coronary intervention

Clinical Trials

Ongoing Trials on Adjuncts for high risk percutaneous coronary intervention at Clinical Trials.gov

Trial results on Adjuncts for high risk percutaneous coronary intervention

Clinical Trials on Adjuncts for high risk percutaneous coronary intervention at Google

Guidelines / Policies / Govt

US National Guidelines Clearinghouse on Adjuncts for high risk percutaneous coronary intervention

NICE Guidance on Adjuncts for high risk percutaneous coronary intervention

NHS PRODIGY Guidance

FDA on Adjuncts for high risk percutaneous coronary intervention

CDC on Adjuncts for high risk percutaneous coronary intervention

Books

Books on Adjuncts for high risk percutaneous coronary intervention

News

Adjuncts for high risk percutaneous coronary intervention in the news

Be alerted to news on Adjuncts for high risk percutaneous coronary intervention

News trends on Adjuncts for high risk percutaneous coronary intervention

Commentary

Blogs on Adjuncts for high risk percutaneous coronary intervention

Definitions

Definitions of Adjuncts for high risk percutaneous coronary intervention

Patient Resources / Community

Patient resources on Adjuncts for high risk percutaneous coronary intervention

Discussion groups on Adjuncts for high risk percutaneous coronary intervention

Patient Handouts on Adjuncts for high risk percutaneous coronary intervention

Directions to Hospitals Treating Adjuncts for high risk percutaneous coronary intervention

Risk calculators and risk factors for Adjuncts for high risk percutaneous coronary intervention

Healthcare Provider Resources

Symptoms of Adjuncts for high risk percutaneous coronary intervention

Causes & Risk Factors for Adjuncts for high risk percutaneous coronary intervention

Diagnostic studies for Adjuncts for high risk percutaneous coronary intervention

Treatment of Adjuncts for high risk percutaneous coronary intervention

Continuing Medical Education (CME)

CME Programs on Adjuncts for high risk percutaneous coronary intervention

International

Adjuncts for high risk percutaneous coronary intervention en Espanol

Adjuncts for high risk percutaneous coronary intervention en Francais

Business

Adjuncts for high risk percutaneous coronary intervention in the Marketplace

Patents on Adjuncts for high risk percutaneous coronary intervention

Experimental / Informatics

List of terms related to Adjuncts for high risk percutaneous coronary intervention

Cardiology Network

Discuss Adjuncts for high risk percutaneous coronary intervention further in the WikiDoc Cardiology Network
Adult Congenital
Biomarkers
Cardiac Rehabilitation
Congestive Heart Failure
CT Angiography
Echocardiography
Electrophysiology
Cardiology General
Genetics
Health Economics
Hypertension
Interventional Cardiology
MRI
Nuclear Cardiology
Peripheral Arterial Disease
Prevention
Public Policy
Pulmonary Embolism
Stable Angina
Valvular Heart Disease
Vascular Medicine

Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1] ; Cafer Zorkun, M.D., Ph.D. [2]


Intraaortic Balloon Pump (IABP)

Description

The IABP is a polyethylene balloon mounted on a catheter, which is generally inserted into the aorta through the femoral artery in the leg. The pump is available in a wide range of sizes (2.5 cc to 50 cc) that will fit patients of any age and size. The balloon is guided into the descending aorta, approximately 2 cm from the left subclavian artery. At the start of diastole, the balloon inflates, augmenting coronary perfusion. At the beginning of systole, the balloon deflates; blood is ejected from the left ventricle, increasing the cardiac output by as much as 40 percent and decreasing the left ventricular stroke work and myocardial oxygen requirements. In this manner, the balloon supports the heart indirectly.

The balloon is inflated with helium, an inert gas that is easily absorbed into the bloodstream in case of rupture. Inflation of the balloon can be triggered according to the patient's electrocardiogram, their blood pressure, a pacemaker (if they have one), or by a pre-set internal rate. Optimal management of balloon timing and volume is guided by direct pressure reading. If no pressure wave is available, the ECG may be used for timing the balloon. The system is operated by an external console.

The IABP has two main benefits:

  • The inflation of the balloon displaces an amount of blood to the ascending aorta which increases the pressure there and consequently increases the flow in the coronary arteries.
  • The deflation of the balloon generates an expansion wave which decreases end diastolic aortic pressure and consequently reduces left ventricular myocardial oxygen requirements in the following beat.

History

In 1958 Harken described for the first time a method to treat left ventricular failure by using counterpulsation or diastolic augmentation. He suggested removing a certain blood volume from the femoral artery during systole and replacing this volume rapidly during diastole. By increasing coronary perfusion pressure this concept would therefore augment cardiac output and unload the functioning heart simultaneously. This method of treatment was limited because of problems with access (need for arteriotomies of both femoral arteries), turbulence and development of massive hemolysis by the pumping apparatus. Even experimental data showed that no augmentation of coronary blood flow was obtained.

In 1961 Clauss et al. introduced their study on arterial counterpulsation concept.

In 1962 Moulopoulus et al. adapted counterpulsation to intra-aortic balloon pumping and developed an experimental prototype of the intra-aortic balloon (IAB) whose inflation and deflation were timed to the cardiac cycle.

In 1968 the initial use in clinical practice of the IABP and it`s further improvement was realized respectfully continued by Kantrowiz`s group.

In its first years, the IABP required surgical insertion and surgical removal with a balloons size of 15 French.

In 1979, the IAB was adapted for percutaneous insertion by Bregman and Casarella, and this was followed in the early 1980s by a dual lumen, wire guided,smaller catheter device which could be placed in couple of minutes with significantly improved insertion success and reduced vascular complications.

In 1985 the first prefolded IAB was developed. These improvements permit safer use and earlier intervention to provide hemodynamic support. These advances made it for even nonsurgical personnel possible to perform an IAB insertion at the patient’s bedside. Refinements have reduced the catheter size to 8F and 9F for 30 to 50 cc balloons, and technically advanced consoles can rapidly shuttle the helium gas with automatic timing.

Factors affecting diastolic augmentation

  • Patient hemodynamics
    • Heart rate
    • Stroke volume
    • Mean arterial pressure
    • Systemic vascular resistance
  • IABP related mechanical factors
    • Intra aortic balloon position
    • Intra aortic balloon in sheath
    • Intra aortic balloon not unfolded
    • Kink in intra aortic balloon catheter
    • Intra aortic balloon leak
    • Low helium concentration
  • IABP console related factors
    • Timing
    • Position of intra aortic balloon augmentation dial

Indications & Contraindications

Indications

  • Refractory unstable angina
  • Impending infarction
  • Acute Myocardial Infarction
  • Refractory ventricular failure
  • Complications of acute MI (Acute Mitral Regurgitation, Ventricular Septal Defect, Papillary muscle rupture)
  • Cardiogenic shock
  • Support for diagnostic coronary angiographies and percutaneous coronary ınterventions
  • Ischemia related intractable ventricular arrhythmias
  • Septic shock
  • Intraoperative pulsatile flow generation
  • Weaning from bypass surgery
  • Cardiac support for non-cardiac surgery
  • Prophylactic support in preparation for cardiac surgery
  • Post surgical myocardial dysfunction / low cardiac output syndrome
  • Myocardial contusion
  • Mechanical bridge to other assist devices
  • Cardiac support following correction of anatomical defects

Contraindications

  • Anatomic abnormality of femoral or iliac arteries
  • Iliac or aortic atherosclerotic disease impairing blood flow run off
  • Aorto femoral grafts
  • Moderate or severe aortic regurgitation
  • Artificial aortic valves
  • Aortic dissection or aneurysm
  • Patent ductus (counterpulsation may augment the abnormal pathway of aortic to pulmoner artery shunting)
  • Bleeding diathesis
  • Sepsis
  • Sheathless insertion with severe obesity, scarring of the groin

Balloon Pump Inserting and Removal Techniques

In the early years of IABP - therapy, insertion of the balloon was performed by surgical cut down to the femoral vessels. After a longitudinal incision in the groin, the femoral arteries were identified and controlled. A vascular graft was then sewn to the common femoral artery in an end-to-side fashion. The balloon was introduced into the artery via the graft and properly positioned in the thoracic aorta and the graft tightly secured to the distal portion of the balloon catheter. Finally the skin incision was closed. Removal of the balloon required a second operation.

Since 1979, a percutaneous placement of the IAB via the femoral artery using a modified Seldinger technique allows an easy and rapid insertion in the majority of situations. After puncture of the femoral artery a J-shaped guide wire is inserted to the level of the aortic arch and then the needle is removed. The arterial puncture side is enlarged with the successive placement of an 8 to 10,5 Fr dilator/sheath combination. Only the dilator needs to be removed. Continuing, the balloon is threaded over the guide wire into the descending aorta just below (app. 1.5 - 2 cm) the left subclavian artery. The sheath is gently pulled back to connect with the leak-proof cuff on the balloon hub, ideally so that the entire sheath is out of the arterial lumen to minimize risk of ischemic complications to the distal extremity. Recently sheathless insertion kits are available. Removal of a percutaneously placed IAB may either be via surgical removal or closed technique. There are alternative routes for balloon insertion include subclavian, axillary or iliac arteries.

Insertion of a counterpulsation balloon without a leading guidewire under any circumstances is not recommended.

When clinically indicated the balloon can be removed (before removal of IAB the patient is weaned progressively from support (decreasing the counterpulsation rate from 1:1 to 1:2 and then 1:3 but should not be reduced below 1:8 to reduce the change of clot formation until immediately before balloon removal) by aspirating negative pressure on the balloon lumen and withdrawing balloon and sheath together (once the balloon has been inflated, its deflated profile is larger than the sheath lumen, and therefore it cannot completely withdrawn into sheath before removal) while compressing the puncture site. The femoral artery compressed below the puncture site as the catheter and sheath are removed to avoid embolism to the leg. Anticoagulation should be discontinued 4 hours before and a partial thromboplastin time (PTT) or activated clotting time (ACT) should be checked before the balloon is removal. Pressure over the groin must be maintened for 30 to 60 minutes.

Assessment of patients and maintenance of IABP

  • Evaluation(daily): All patients with IABP should carefully evaluated for
    • Infection
    • Thrombocytopenia: After balloon removal, the platelet count rapidly returns to normal
    • Hemorrhage
    • Hemolysis
    • Vascular obstruction with limb ischemia; regular examination of radial and dorsalis pedis arteries may be helpful for quick evaluation of peripheral arteries.
  • Maintenance

Heparin administration (5000 U bolus and 1000 U/hr) is almost a standard practice.

When performing angiography or PCI from the contralateral femoral artery a J wire is used. The balloon is placed on standby while the wire and catheter pass the balloon so that damage is minimized.

  • Control of IABP

To achieve optimal effect of intra aortic balloon counterpulsation, inflation and deflation need to be correctly timed to the patient’s cardiac cycle. This is accomplished by either using the patient’s ECG signal, the patient’s arterial waveform or an intrinsic pump rate. The most common method of triggering the IAB is from the R wave of the patient’s ECG signal. Mainly balloon inflation is set automatically to start in the middle of the T wave and to deflate prior to the ending QRS complex.

Tachyarrhythmias, cardiac pacemaker function and poor ECG signals may cause difficulties in obtaining synchronization when the ECG mode is used. In such cases the arterial waveform for triggering may be used.

  • Duration of Intra Aortic Balloon Support

The balloon is usually removed once the patient has stabilized after the acute insult.

Complications

The success rate for percutaneous inserton of IAB is more than 90%. If signs of ischemia appear the balloon should be removed. In general, vascular injuries should be dealt with directly by surgical interventions and repair. Balloon related problems and infection require removal and / or replacement of the intra aortic balloon. Complications include:

  • Vascular
    • Femoral artery perforation & dissection
    • Aortic perforation & dissection
    • Femoral artery thrombosis
    • Peripheral embolization
    • Femoral vein cannulation
    • A-V fistula
    • False aneurysm
    • Limb ischemia
    • Visceral ischemia
  • Balloon related
    • Perforation
    • Tear
    • Rupture
    • Incorrect positioning
    • Gas embolization
  • Others
    • Hemorrhage (haematomas)
    • Infection
    • Broken and missing balloon & catheter parts

Role of IABP in high risk coronary interventions

Although, prophylactic use of Intra Aortic Balloon Pump may provide circulatory support during percutaneous coronary interventions in patients at high risk for procedure related morbidity and mortality, usefulness of elective IABP support in patients at high risk for complications during PCI is still controversial.

Patients with pharmacologically uncontrollable chest pain, high-risk anatomic features, unprotected left main coronary artery stenosis, last remaining vessel supply, same session multivessel complex coronary interventions, coronary disease with ventricular dysfunction and severe left ventricular systolic dysfunction are likely get benefit from previous hemodynamic stabilization because even transient ischemia may produce a fatal complication.

IABP therapy provides an increase in coronary artery perfusion pressure, reducing the hemodynamic consequences of reduced coronary flow during balloon inflation and other PCI modalities. Placement and institution of IABP therapy before intervening, as opposed to provisional IABP therapy only if complications occur, may prevent intraprocedural cardiac and cerebral complications

References

  • Kreidieh I, Davies DW, Lim R, Nathan AW, Dymond DS, Banim SO. High-risk coronary angioplasty with elective intra-aortic balloon pump support. Int J Cardiol 1992, 35, 147–52
  • Aguirre FV, Kern MJ, Bach R, Donohue T, Caracciolo E, Flynn MS, Wolford T. Intraaortic balloon pump support during high-risk coronary angioplasty. Cardiology 1994, 84, 175–86
  • Szatmary L, Marco J, Fajadet J, Caster L, Carrie D. Intraaortic balloon counterpulsation and coronary angioplasty in high risk coronary heart patients. Acta Med Hung 1987, 44, 189–200
  • Stone GW, Ohman EM, Miller MF, et. al. Contemporary utilization and outcomes of intra-aortic balloon counterpulsation in acute myocardial infarction: the Benchmark Registry. J Am Coll Cardiol 2003, 41, 1940-45.

ECHMO

Percutaneous Bypass


Template:WikiDoc Sources