Plummer-Vinson syndrome laboratory findings: Difference between revisions

Jump to navigation Jump to search
No edit summary
No edit summary
Line 4: Line 4:


==Overview==
==Overview==
Laboratory findings consistent with the diagnosis of Plummer-Vinson syndrome include presence of iron deficiency anemia. In patients with iron deficiency anemia the best initial test is a complete blood count(CBC) and the most accurate test is bone marrow biopsy for stainable iron. Patients suspected with Plummer-Vinson syndrome should also be tested with iron studies, peripheral smear, stool test for occult blood, and blood lead levels.
Laboratory findings consistent with the diagnosis of Plummer-Vinson syndrome include presence of iron deficiency anemia. Patients suspected with Plummer-Vinson syndrome should be tested with complete blood count (CBC), iron studies, peripheral smear, stool test for occult blood, blood lead levels and bone marrow biopsy for stainable iron.


==Laboratory Findings==
==Laboratory Findings==

Revision as of 16:16, 26 October 2017

Plummer-Vinson syndrome Microchapters

Home

Patient Information

Overview

Historical Perspective

Classification

Pathophysiology

Causes

Differentiating Plummer-Vinson syndrome from other Diseases

Epidemiology and Demographics

Risk Factors

Screening

Natural History, Complications and Prognosis

Diagnosis

Diagnostic Criteria

History and Symptoms

Physical Examination

Laboratory Findings

Electrocardiogram

X Ray

Echocardiography and Ultrasound

CT

MRI

Other Imaging Findings

Other Diagnostic Studies

Treatment

Medical Therapy

Surgery

Primary Prevention

Secondary Prevention

Cost-Effectiveness of Therapy

Future or Investigational Therapies

Case Studies

Case #1

Plummer-Vinson syndrome laboratory findings On the Web

Most recent articles

Most cited articles

Review articles

CME Programs

Powerpoint slides

Images

American Roentgen Ray Society Images of Plummer-Vinson syndrome laboratory findings

All Images
X-rays
Echo & Ultrasound
CT Images
MRI

Ongoing Trials at Clinical Trials.gov

US National Guidelines Clearinghouse

NICE Guidance

FDA on Plummer-Vinson syndrome laboratory findings

CDC on Plummer-Vinson syndrome laboratory findings

Plummer-Vinson syndrome laboratory findings in the news

Blogs on Plummer-Vinson syndrome laboratory findings

Directions to Hospitals Treating Plummer-Vinson syndrome

Risk calculators and risk factors for Plummer-Vinson syndrome laboratory findings

Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1];Associate Editor(s)-in-Chief:

Overview

Laboratory findings consistent with the diagnosis of Plummer-Vinson syndrome include presence of iron deficiency anemia. Patients suspected with Plummer-Vinson syndrome should be tested with complete blood count (CBC), iron studies, peripheral smear, stool test for occult blood, blood lead levels and bone marrow biopsy for stainable iron.

Laboratory Findings

Laboratory findings consistent with the diagnosis of Plummer-Vinson syndrome include presence of iron deficiency anemia:[1][2][3][4][5][6][7][8]

  • Complete blood count should be done in patients of Plummer-Vinson syndrome and will have the following findings:
    • Low mean corpuscular volume (MCV <80 fl)
    • Low mean corpuscular hemoglobin concentration (MCHC)
    • Elevated platelet count (platelets > 450,000/µL)
    • Normal or elevated white blood cell count
  • Iron studies should be done in patients with pallor, dysphagia or esophageal webs to confirm the diagnosis of Plummer-Vinson syndrome. The tests usually done for iron deficiency anemia are:
Change in lab values in iron deficiency anemia
Change Parameter
Decrease Hemoglobin, Ferritin, MCV
Increase TIBC, Transferrin, RDW
  • Peripheral smear:
    • RBCs are microcytic and hypochromic
    • Increased number of platelets
    • Target cells (can be seen in any case of anemia)
    • Presence of ringed sideroblasts and basophilic stippling
  • Other test includes:
    • Stool testing: It should be done in all men and postmenopausal women who present with iron deficiency anemia to rule out colonic polyps and malignancy.
    • Blood lead levels: It is done in cases of
    • Bone marrow aspiration for stainable iron: This the most accurate test to determine iron deficiency. However, it is not routinely done, since other blood and iron studies are reliable source to determine the presence of iron deficiency anemia.

References

  1. Guyatt G, Patterson C, Ali M, Singer J, Levine M, Turpie I, Meyer R (1990). "Diagnosis of iron-deficiency anemia in the elderly". Am J Med. 88 (3): 205–9. PMID 2178409.
  2. Hempel EV, Bollard ER (2016). "The Evidence-Based Evaluation of Iron Deficiency Anemia". Med. Clin. North Am. 100 (5): 1065–75. doi:10.1016/j.mcna.2016.04.015. PMID 27542426.
  3. Parkin PC, Maguire JL (2013). "Iron deficiency in early childhood". CMAJ. 185 (14): 1237–8. doi:10.1503/cmaj.130150. PMC 3787170. PMID 23922344.
  4. Mazza J, Barr RM, McDonald JW, Valberg LS (1978). "Usefulness of the serum ferritin concentration in the detection of iron deficiency in a general hospital". Can Med Assoc J. 119 (8): 884–6. PMC 1819106. PMID 737638.
  5. Thomason RW, Almiski MS (2009). "Evidence that stainable bone marrow iron following parenteral iron therapy does not correlate with serum iron studies and may not represent readily available storage iron". Am. J. Clin. Pathol. 131 (4): 580–5. doi:10.1309/AJCPBAY9KRZF8NUC. PMID 19289594.
  6. Kis AM, Carnes M (1998). "Detecting iron deficiency in anemic patients with concomitant medical problems". J Gen Intern Med. 13 (7): 455–61. PMC 1496985. PMID 9686711.
  7. Allali S, Brousse V, Sacri AS, Chalumeau M, de Montalembert M (2017). "Anemia in children: prevalence, causes, diagnostic work-up, and long-term consequences". Expert Rev Hematol: 1–6. doi:10.1080/17474086.2017.1354696. PMID 29023171.
  8. Liberti ME, Garofalo C, Sagliocca A, Borrelli S, Conte G, De Nicola L, Minutolo R (2017). "[Iron deficiency in ND-CKD: from diagnosis to treatment]". G Ital Nefrol (in Italian). 34 (5): 50–61. PMID 28963827.

Template:WH Template:WS