Second degree AV block primary prevention: Difference between revisions

Jump to navigation Jump to search
Line 10: Line 10:


* Pacemaker implantations as a treatment for atrioventricular (AV) block are increasing worldwide. Prevention strategies for AV block are lacking because modifiable risk factors have not yet been identified<ref name="pmid31125096">{{cite journal |vauthors=Kerola T, Eranti A, Aro AL, Haukilahti MA, Holkeri A, Junttila MJ, Kenttä TV, Rissanen H, Vittinghoff E, Knekt P, Heliövaara M, Huikuri HV, Marcus GM |title=Risk Factors Associated With Atrioventricular Block |journal=JAMA Netw Open |volume=2 |issue=5 |pages=e194176 |date=May 2019 |pmid=31125096 |pmc=6632153 |doi=10.1001/jamanetworkopen.2019.4176 |url=}}</ref>.
* Pacemaker implantations as a treatment for atrioventricular (AV) block are increasing worldwide. Prevention strategies for AV block are lacking because modifiable risk factors have not yet been identified<ref name="pmid31125096">{{cite journal |vauthors=Kerola T, Eranti A, Aro AL, Haukilahti MA, Holkeri A, Junttila MJ, Kenttä TV, Rissanen H, Vittinghoff E, Knekt P, Heliövaara M, Huikuri HV, Marcus GM |title=Risk Factors Associated With Atrioventricular Block |journal=JAMA Netw Open |volume=2 |issue=5 |pages=e194176 |date=May 2019 |pmid=31125096 |pmc=6632153 |doi=10.1001/jamanetworkopen.2019.4176 |url=}}</ref>.
* pacemakers can usually provide adequate treatment of the symptoms of AV block, no preventive or curative strategies are currently used in clinical practice.
* pacemaker implantation can involve a risk of serious complications, such as pneumothorax, cardiac tamponade, and death.9 After implantation, patients require generator changes, which carry a particularly high risk of infection and resultant endocarditis.10 Finally, independent of these procedural complications, successful pacemaker therapy has been associated with a worse prognosis.11,12,13
A better understanding of the conditions associated with severe AV conduction disease would enable the development of prevention strategies, ideally avoiding the pacemaker-associated complications and increased use of health care resources. No previous study, to our knowledge, has reported the population-based characteristics associated with incident AV block. We therefore sought to identify risk factors for AV block, with a particular emphasis on characteristics that are known to be modifiable.


==References==
==References==

Revision as of 20:14, 9 April 2020

Second degree AV block Microchapters

Home

Patient Information

Overview

Historical Perspective

Classification

Pathophysiology

Causes

Differentiating Second degree AV block from other Diseases

Epidemiology and Demographics

Risk Factors

Screening

Natural History, Complications and Prognosis

Diagnosis

Diagnostic Study of Choice

History and Symptoms

Physical Examination

Laboratory Findings

Electrocardiogram

EKG Examples

Chest X Ray

Echocardiography

Other Imaging Findings

Other Diagnostic Studies

Treatment

Medical Therapy

Surgery

Primary Prevention

Secondary Prevention

Cost-Effectiveness of Therapy

Future or Investigational Therapies

Case Studies

Case #1

Second degree AV block primary prevention On the Web

Most recent articles

Most cited articles

Review articles

CME Programs

slides

Images

American Roentgen Ray Society Images of Second degree AV block primary prevention

All Images
X-rays
Echo & Ultrasound
CT Images
MRI

Ongoing Trials at Clinical Trials.gov

US National Guidelines Clearinghouse

NICE Guidance

FDA on Second degree AV block primary prevention

CDC on Second degree AV block primary prevention

Second degree AV block primary prevention in the news

Blogs on Second degree AV block primary prevention

Directions to Hospitals Treating Second degree AV block

Risk calculators and risk factors for Second degree AV block primary prevention

Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]; Associate Editor(s)-in-Chief:

Overview

Pacemaker implantations as a treatment for atrioventricular (AV) block are increasing worldwide. Prevention strategies for AV block are lacking because modifiable risk factors have not yet been identified.Atrioventricular (AV) block is a common reason for pacemaker implantation, and the number of pacemaker implantations is increasing.1 Atrioventricular block most commonly occurs in the absence of significant cardiac disease and is generally attributed to idiopathic fibrosis of the conduction system.2 By definition, the cause of that fibrosis remains unknown.

Primary prevention

  • Pacemaker implantations as a treatment for atrioventricular (AV) block are increasing worldwide. Prevention strategies for AV block are lacking because modifiable risk factors have not yet been identified[1].
  • pacemakers can usually provide adequate treatment of the symptoms of AV block, no preventive or curative strategies are currently used in clinical practice.
  • pacemaker implantation can involve a risk of serious complications, such as pneumothorax, cardiac tamponade, and death.9 After implantation, patients require generator changes, which carry a particularly high risk of infection and resultant endocarditis.10 Finally, independent of these procedural complications, successful pacemaker therapy has been associated with a worse prognosis.11,12,13

A better understanding of the conditions associated with severe AV conduction disease would enable the development of prevention strategies, ideally avoiding the pacemaker-associated complications and increased use of health care resources. No previous study, to our knowledge, has reported the population-based characteristics associated with incident AV block. We therefore sought to identify risk factors for AV block, with a particular emphasis on characteristics that are known to be modifiable.

References

  1. Kerola T, Eranti A, Aro AL, Haukilahti MA, Holkeri A, Junttila MJ, Kenttä TV, Rissanen H, Vittinghoff E, Knekt P, Heliövaara M, Huikuri HV, Marcus GM (May 2019). "Risk Factors Associated With Atrioventricular Block". JAMA Netw Open. 2 (5): e194176. doi:10.1001/jamanetworkopen.2019.4176. PMC 6632153 Check |pmc= value (help). PMID 31125096.


Template:WikiDoc Sources