Revision as of 15:14, 13 August 2012

WikiDoc Resources for Mechanical ventilation

Articles

Most recent articles on Mechanical ventilation

Most cited articles on Mechanical ventilation

Review articles on Mechanical ventilation

Articles on Mechanical ventilation in N Eng J Med, Lancet, BMJ

Media

Powerpoint slides on Mechanical ventilation

Images of Mechanical ventilation

Photos of Mechanical ventilation

Podcasts & MP3s on Mechanical ventilation

Videos on Mechanical ventilation

Evidence Based Medicine

Cochrane Collaboration on Mechanical ventilation

Bandolier on Mechanical ventilation

TRIP on Mechanical ventilation

Clinical Trials

Ongoing Trials on Mechanical ventilation at Clinical Trials.gov

Trial results on Mechanical ventilation

Clinical Trials on Mechanical ventilation at Google

Guidelines / Policies / Govt

US National Guidelines Clearinghouse on Mechanical ventilation

NICE Guidance on Mechanical ventilation

NHS PRODIGY Guidance

FDA on Mechanical ventilation

CDC on Mechanical ventilation

Books

Books on Mechanical ventilation

News

Mechanical ventilation in the news

Be alerted to news on Mechanical ventilation

News trends on Mechanical ventilation

Commentary

Blogs on Mechanical ventilation

Definitions

Definitions of Mechanical ventilation

Patient Resources / Community

Patient resources on Mechanical ventilation

Discussion groups on Mechanical ventilation

Patient Handouts on Mechanical ventilation

Directions to Hospitals Treating Mechanical ventilation

Risk calculators and risk factors for Mechanical ventilation

Healthcare Provider Resources

Symptoms of Mechanical ventilation

Causes & Risk Factors for Mechanical ventilation

Diagnostic studies for Mechanical ventilation

Treatment of Mechanical ventilation

Continuing Medical Education (CME)

CME Programs on Mechanical ventilation

International

Mechanical ventilation en Espanol

Mechanical ventilation en Francais

Business

Mechanical ventilation in the Marketplace

Patents on Mechanical ventilation

Experimental / Informatics

List of terms related to Mechanical ventilation

Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]

Overview

In medicine, mechanical ventilation is a method to mechanically assist or replace spontaneous breathing when patients cannot do so on their own, and must be done so after invasive intubation with an endotracheal or tracheostomy tube through which air is directly delivered (in contrast to noninvasive ventilation). In many cases, mechanical ventilation is used in acute settings such as in the ICU for a short period of time during a serious illness. For some patients who have certain chronic illnesses that require long-term ventilation assistance, they are also able to do so at home or other nursing/rehabilitation institution with the help of respiratory therapists and physicians. The main form of mechanical ventilation currently is positive pressure ventilation, which works by increasing the pressure in the patient's airway and thus forcing additional air into the lungs. This is in contrast to the more historically common negative pressure ventilators (for example, the "iron lung") that create a negative pressure environment around the patient's chest, thus sucking air into the lungs. Although often a life-saving technique, mechanical ventilation carries many potential complications including pneumothorax, airway injury, alveolar damage, and ventilator-associated pneumonia, among others. Accordingly it is generally weaned off or to minimal settings as soon as possible.

Nasotracheal intubation

History

Vesalius was the first person to describe mechanical ventilation by inserting a reed or cane into the trachea of animals and then blowing into this tube.[1]

Negative pressure machines

Iron Lung

The iron lung, also known as the Drinker and Shaw tank, was developed in 1929 and was one of the first negative-pressure machines used for long-term ventilation. It was refined and used in the 20th century largely as a result of the polio epidemic that struck the world in the 1950s. The machine is effectively a large elongated tank, which encases the patient up to the neck. The neck is sealed with a rubber gasket so that the patient's face (and airway) are exposed to the room air.

While the exchange of oxygen and carbon dioxide between the bloodstream and the pulmonary airspace works by diffusion and requires no external work, air must be moved into and out of the lungs to make it available to the gas exchange process. In spontaneous breathing, a negative pressure is created in the pleural cavity by the muscles of respiration, and the resulting gradient between the atmospheric pressure and the pressure inside the thorax generates a flow of air.

In the iron lung by means of a pump, the air is withdrawn mechanically to produce a vacuum inside the tank, thus creating negative pressure. This negative pressure leads to expansion of the chest, which causes a decrease in intrapulmonary pressure and flow of ambient air into the lungs. As the vacuum is released, the pressure inside the tank equalizes to that of the ambient pressure, and the elastic coil of the chest and lungs leads to passive exhalation. However, when the vacuum is created, the abdomen also expands along with the lung, cutting off venous flow back to the heart, leading to pooling of venous blood in the lower extremities. There are large portholes for nurse or home assistant access. The patients can talk and eat normally, and can see the world through a well-placed series of mirrors. Some could remain in these iron lungs for years at a time quite successfully.

Today, negative pressure mechanical ventilators are still in use, notably with the Polio Wing Hospitals in England such as St Thomas' (by Westminster in London) and the John Radcliffe in Oxford. The prominent device used is a smaller device known as the cuirass. The cuirass is a shell-like unit, creating negative pressure only to the chest using a combination of a fitting shell and a soft bladder. Its main use is in patients with neuromuscular disorders who have some residual muscular function. However, it was prone to falling off and caused severe chafing and skin damage and was not used as a long term device. In recent years this device has re-surfaced as a modern polycarbonate shell with multiple seals and a high pressure oscillation pump in order to carry out biphasic cuirass ventilation.

Positive pressure machines

Mechanical ventilator

The design of the modern positive-pressure ventilators were mainly based on technical developments by the military during World War II to supply oxygen to fighter pilots in high altitude. Such ventilators replaced the iron lungs as safe endotracheal tubes with high volume/low pressure cuffs were developed. The popularity of positive-pressure ventilators rose during the polio epidemic in the 1950s in Scandinavia and the United States. Positive pressure through manual supply of 50% oxygen through a tracheostomy tube led to a reduced mortality rate among patients with polio and respiratory paralysis. However, because of the sheer amount of man-power required for such intervention, positive-pressure ventilators became increasingly popular.

Positive-pressure ventilators work by increasing the patient's airway pressure through an endotracheal or tracheostomy tube. The positive pressure allows air to flow into the airway until the ventilator breath is terminated. Subsequently, the airway pressure drops to zero, and the elastic recoil of the chest wall and lungs push the tidal volume -- the breath -- out through passive exhalation.

Indications for use

Mechanical ventilation is indicated when the patient's spontaneous ventilation is inadequate to maintain life. It is also indicated as prophylaxis for imminent collapse of other physiologic functions, or ineffective gas exchange in the lungs. Because mechanical ventilation only serves to provide assistance for breathing and does not cure a disease, the patient's underlying condition should be correctable and should resolve over time. In addition, other factors must be taken into consideration because mechanical ventilation is not without its complications (see below)

Common medical indications for use include:

Types of ventilators

Ventilation can be delivered via:

  • Hand-controlled ventilation such as:
    Bag valve mask
  • A mechanical ventilator. Types of mechanical ventilators include:
    • Transport ventilators. These ventilators are small, more rugged, and can be powered pneumatically or via AC or DC power sources.
    • ICU ventilators. These ventilators are larger and usually run on AC power (though virtually all contain a battery to facilitate intrafacility transport and as a back-up in the event of a power failure). This style of ventilator often provides greater control of a wide variety of ventilation parameters (such as inspiratory rise time). Many ICU ventilators also incorporate graphics to provide visual feedback of each breath.
      • NICU ventilators. Designed with the preterm neonate in mind, these are a specialized subset of ICU ventilators which are designed to deliver the smaller, more precise volumes and pressures required to ventilate these patients.
    • PAP ventilators. these ventilators are specifically designed for non-invasive ventilation. this includes ventilators for use at home, in order to treat sleep apnea.

Modes of ventilation

Conventional ventilation

The modes of ventilation can be thought of as classifications based on how to control the ventilator breath. Traditionally ventilators were classified based on how they determined when to stop giving a breath. The three traditional categories of ventilators are listed below. As microprocessor technology is incorporated into ventilator design, the distinction among these types has become less clear as ventilators may use combinations of all of these modes as well as flow-sensing, which controls the ventilator breath based on the flow-rate of gas versus a specific volume, pressure, or time.

Breath termination

  • In a volume-cycled ventilator the ventilator delivers a preset volume of gas with each breath. Once the specified volume of breath is delivered, the positive pressure is terminated.
  • In a pressure-cycled ventilator, once a preset pressure is reached within the ventilator, the breath is terminated.
  • In a time-cycled ventilator, the termination of the breath occurs after a certain specified time period.

Both pressure and volume modes of ventilation have their respective limitations. Many manufacturers provide a mode or modes that utilize some functions of each. These modes are flow-variable, volume-targeted, pressure-regulated, time-limited modes (for example, pressure-regulated volume control - PRVC). This means that instead of providing an exact tidal volume each breath, a target volume is set and the ventilator will vary the inspiratory flow at each breath to achieve the target volume at the lowest possible peak pressure. The inspiratory time limits the length of the inspiratory cycle and therefore the I:E ratio. Pressure regulated modes such as PRVC or Auto-flow (Draeger) can most easily be thought of as turning a volume mode into a pressure mode with the added benefit of maintaining more control over tidal volume than with strictly pressure-control.

Breath initiation

The other method of classifying mechanical ventilation is based on how to determine when to start giving a breath. Similar to the termination classification noted above, microprocessor control has resulted in a myriad of hybrid modes that combine features of the traditional classifications. Note that most of the timing initiation classifications below can be combined with any of the termination classifications listed above.

  • Assist Control (AC). In this mode the ventilator provides a mechanical breath with either a preset tidal volume or peak pressure every time the patient initiates a breath. Traditional assist-control used only a preset tidal volume--when a preset peak pressure is used this is also sometimes termed Intermittent Positive Pressure Ventilation or IPPV. However the initiation timing is the same--both provide a ventilator breath with every patient effort. In most ventilators a back-up minimum breath rate can be set in the event that the patient becomes apneic. Although a maximum rate is not usually set, an alarm can be set if the ventilator cycles too frequently. This can alert that the patient is tachypneic or that the ventilator may be auto-cycling (a problem that results when the ventilator interprets fluctuations in the circuit due to the last breath termination as a new breath initiation attempt).
  • Synchronized Intermittent Mandatory Ventilation (SIMV). In this mode the ventilator provides a preset mechanical breath (pressure or volume limited) every specified number of seconds (determined by dividing the respiratory rate into 60 - thus a respiratory rate of 12 results in a 5 second cycle time). Within that cycle time the ventilator waits for the patient to initiate a breath using either a pressure or flow sensor. When the ventilator senses the first patient breathing attempt within the cycle, it delivers the preset ventilator breath. If the patient fails to initiate a breath, the ventilator delivers a mechanical breath at the end of the breath cycle. Additional spontaneous breaths after the first one within the breath cycle do not trigger another SIMV breath. However, SIMV may be combined with pressure support (see below). SIMV is frequently employed as a method of decreasing ventilatory support (weaning) by turning down the rate, which requires the patient to take additional breaths beyond the SIMV triggered breath.
  • Controlled Mechanical Ventilation (CMV). In this mode the ventilator provides a mechanical breath on a preset timing. Patient respiratory efforts are ignored. This is generally uncomfortable for children and adults who are conscious and is usually only used in an unconscious patient. It may also be used in infants who often quickly adapt their breathing pattern to the ventilator timing.
  • Pressure Support Ventilation (PSV). This was developed as a method to decrease the work of breathing in-between ventilator mandated breaths. Thus, for example, SIMV might be combined with PSV so that additional breaths beyond the SIMV programmed breaths are supported. However, while the SIMV mandated breaths have a preset volume or peak pressure, the PSV breaths are designed to cut short when the inspiratory flow reaches a percentage of the peak inspiratory flow (e.g. 10-25%). Also, the peak pressure set for the PSV breaths is usually a lower pressure than that set for the SIMV breath. PSV can be also be used as an independent mode. However, since there is generally no back-up rate in PSV, appropriate apnea alarms must be set on the ventilator.
  • Continuous Positive Airway Pressure (CPAP). A continuous level of elevated pressure is provided through the patient circuit to maintain adequate oxygenation, decrease the work of breathing, and decrease the work of the heart (such as in left-sided heart failure - CHF). Note that no cycling of ventilator pressures occurs and the patient must initiate all breaths. In addition, no additional pressure above the CPAP pressure is provided during those breaths. CPAP may be used invasively through an endotracheal tube or tracheostomy or non-invasively with a face mask or nasal prongs.
  • Positive End Expiratory Pressure (PEEP) is functionally the same as CPAP, but refers to the use of an elevated pressure during the expiratory phase of the ventilatory cycle. After delivery of the set amount of breath by the ventilator, the patient then exhales passively. The volume of gas remaining in the lung after a normal expiration is termed the functional residual capacity (FRC). The FRC is primarily determined by the elastic qualities of the lung and the chest wall. In many lung diseases, the FRC is reduced due to collapse of the unstable alveoli, leading to a decreased surface area for gas exchange and intrapulmonary shunting (see above), with wasted oxygen inspired. Adding PEEP can reduce the work of breathing (at low levels) and help preserve FRC.

High Frequency Ventilation (HFV)

High Frequency ventilator

High-Frequency Ventilation refers to ventilation that occurs at rates significantly above that found in natural breathing (as high as 300-900 "breaths" per minute). Within the category of high-frequency ventilation, the two principal types are flow interruption and high-frequency oscillatory ventilation (HFOV). The former operates similarly to a conventional ventilator, providing increased circuit pressure during the inspiratory phase and dropping back to PEEP during the expiratory phase. In HFOV the pressure wave is driven by an electromagnetically controlled diaphragm similar to a loudspeaker. Because this can rapidly change the volume in the circuit, HFOV can produce a pressure that is lower than ambient pressure during the expiratory phase. This is sometimes called "active" expiration. In both types of high-frequency ventilation the pressure wave that is generated at the ventilator is markedly attenuated by passage down the endotracheal tube and the major conducting airways. This helps protect the alveoli from volutrauma that occurs with traditional positive pressure ventilation. Although the alveoli are kept at a relatively constant volume, similar to CPAP, other mechanisms of gas exchange allow ventilation (the removal of CO2) to occur without tidal volume exchange. Ventilation in HFV is a function of frequency, amplitude, and I:E ratio and is best described graphically as the area under the curve of an oscillatory cycle. Amplitude is analogous to tidal volume in conventional ventilation; larger amplitudes remove more CO2. Paradoxically, lower frequencies remove more CO2 in HFOV whereas in conventional ventilation the opposite is true. As frequency increases, the total time for a single cycle decreases (the oscillatory curve is shortened thereby decreasing the area under the curve and thus ventilation). I-time is set as a percentage of total time (usually 33%). Amplitude is a function of power and is subject to variability due to changes in compliance or resistance. Therefore, power requirements may vary significantly during treatment and from patient to patient. Patient characteristics and ventilator settings determine whether PaCO2 changes may be more sensitive to amplitude or frequency manipulation. In HFOV, mean airway pressure (MAP) is delivered via a continuous flow through the patient circuit which passes through a variable restriction valve (mushroom valve) on the expiratory limb. Increasing the flow through the circuit and/or increasing the pressure in the mushroom valve increases MAP. The MAP in HFOV functions similarly to PEEP in conventional ventilation in that it provides the pressure for alveolar recruitment.

Choosing amongst ventilator modes

Assist-control mode minimizes patient effort by providing full mechanical support with every breath. This is often the initial mode chosen because it provides the greatest degree of support. In patients with less severe respiratory failure, other modes such as SIMV may be appropriate. Assist-control mode should not be used in those patients with a potential for respiratory alkalosis, in which the patient has an increased respiratory drive. Such hyperventilation and hypocapnia (decreased systemic carbon dioxide due to hyperventilation) usually occurs in patients with end-stage liver disease, hyperventilatory sepsis, and head trauma. Respiratory alkalosis will be evident from the initial arterial blood gas obtained, and the mode of ventilation can then be changed if so desired.

Positive End Expiratory Pressure may or may not be employed to prevent atelectasis.

High frequency oscillation is used most frequently in neonates, but is also used as an alternative mode in adults with severe ARDS.

Initial ventilator settings

The following are general guidelines that may need to be modified for the individual patient.

Tidal Volume, Rate, and Pressures

  • For adult patients and older children
    • without existing lung disease -- a tidal volume of 12 mL per kg body weight is set to be delivered at a rate of 12 a minute (12-12 rule).
    • with COPD -- a reduced tidal volume of 10 ml/kg is to be delivered 10 times a minute to prevent overinflation and hyperventilation (10-10 rule).
    • with acute respiratory distress syndrome (ARDS) -- an even more reduced tidal volume of 6-8 mL/kg is used with a rate of 10-12/minute. This reduced tidal volume allows for minimal volutrauma but may result in an elevated pCO2 (due to the relative decreased oxygen delivered) but this elevation does not need to be corrected (termed permissive hypercapnia)
  • For infants and younger children
    • without existing lung disease -- a tidal volume of 4-10 ml/kg to be delivered at a rate of 30-35 breaths per minute
    • with RDS -- decrease tidal volume and increase respiratory rate sufficient to maintain pCO2 between 45-55. Allowing higher pCO2 (sometimes called permissive hypercapnia) may help prevent ventilator induced lung injury

As the amount of tidal volume increases, the pressure required to administer that volume is increased. This pressure is known as the peak airway pressure. If the peak airway pressure is persistently above 45 cmH2O for adults, the risk of barotrauma is increased (see below) and efforts should be made to try to reduce the peak airway pressure. In infants and children it is unclear what level of peak pressure may cause damage. In general, keeping peak pressures below 30 is desirable.

Monitoring for barotrauma can also involve measuring the plateau pressure, which is the pressure after the delivery of the tidal volume but before the patient is allowed to exhale. Normal breathing pattern involves inspiration, then expiration. The ventilator is programmed so that after delivery of the tidal volume (inspiration), the patient is not allowed to exhale for a half a second. Therefore, pressure must be maintained in order to prevent exhalation, and this pressure is the plateau pressure. Barotrauma is minimized when the plateau pressure is maintained < 30-35 cmH2O.

Sighs

An adult patient breathing spontaneously will usually sigh about 6-8 times/hr to prevent microatelectasis, and this has led some to propose that ventilators should deliver 1.5-2 times the amount of the preset tidal volume 6-8 times/hr to account for the sighs. However, such high quantity of volume delivery requires very high peak pressure that predisposes to barotrauma. Currently, accounting for sighs is not recommended if the patient is receiving 10-12 mL/kg or is on PEEP. If the tidal volume used is lower, the sigh adjustment can be used, as long as the peak and plateau pressures are acceptable.

Sighs are not generally used with ventilation of infants and young children.

Initial FiO2

Because the mechanical ventilator is responsible for assisting in a patient's breathing, it must then also be able to deliver an adequate amount of oxygen in each breath. The FiO2 stands for fraction of inspired oxygen, which means the percent of oxygen in each breath that is inspired. (Note that normal room air has ~21% oxygen content). In adult patients who can tolerate higher levels of oxygen for a period of time, the initial FiO2 may be set at 100% until arterial blood gases can document adequate oxygenation. An FiO2 of 100% for an extended period of time can be dangerous, but it can protect against hypoxemia from unexpected intubation problems. For infants, and especially in premature infants, avoiding high levels of FiO2 (>60%) is important.

Positive end-expiratory pressure (PEEP)

PEEP is an adjuvunt to the mode ventilation used in cases where the FRC is reduced. At the end of expiration, the PEEP exerts pressure to oppose passive emptying of the lung and to keep the airway pressure above the atmospheric pressure. The presence of PEEP opens up collapse or unstable alveoli and increases the FRC and surface area for gas exchange, thus reducing the size of the shunt. Thus, if a large shunt is found to exist based on the estimation from 100% FiO2 (see above), then PEEP can be considered and the FiO2 can be lowered (< 60%) to still maintain an adequate PaO2, thus reducing the risk of oxygen toxicity.

In addition to treating a shunt, PEEP is also therapeutic in decreasing the work of breathing. In pulmonary physiology, compliance is a measure of the "stiffness" of the lung and chest wall. The mathematical formula for compliance (C) = change in volume / change in pressure. Therefore, a higher compliance means that only small increases in pressure can lead to large increases in volume, which means the work of breathing is reduced. As the FRC increases with PEEP, the compliance also increases, since the partially inflated lung takes less energy to inflate further.

Indications. PEEP is a cardiodepressant and can cause severe hemodynamic consequences through decreasing venous return to the right heart and decreasing right ventricular. As such, it should be judiciously used and is indicated in two circumstances.

  • If a PaO2 of 60 mmHg cannot be achieved with a FiO2 of 60%
  • If the initial shunt estimation is greater than 25%

If used, PEEP is usually set with the minimal positive pressure to maintain an adequate PaO2 with a safe FiO2. As PEEP increase intrathoracic pressure, there can be a resulting decrease in venous return and decrease in cardiac output. A PEEP of less than 10 cmH2O is usually safe if intravascular volume depletion is absent. Older literature recommended routine placement of a Swan-Ganz catheter if the amount of PEEP used is greater than 10 cmH2 for hemodynamic monitoring. More recent literature has failed to find outcome benefits with routine PA catheterization when compared to simple central venous pressure monitoring.[2] If cardiac output measurement is required, minimally invasive techniques, such as esophageal doppler monitoring or arterial waveform contour monitoring may be sufficient alternatives.[3][4] PEEP should be withdrawn from a patient until adequate PaO2 can be maintained with a FiO2 < 40%. When withdrawing, it is decreased through 1-2 cmH2O decrements while monitoring hemoglobin-oxygen saturations. Any unacceptable hemoglobin-oxygen saturation should prompt reinstitution of the last PEEP level that maintained good saturation.

Positioning

Prone (face down) positioning has been used in patients with ARDS and severe hypoxemia. It improves FRC, drainage of secretions, and ventilation-perfusion matching (efficiency of gas exchange). It may improve oxygenation in > 50% of patients, but no survival benefit has been documented.

Sedation

Most patients receive sedation through a continuous infusion or scheduled dosing to help with anxiety or psychological stress. Daily interruption of sedation is commonly helpful to the patient for reorientation and appropriate weaning.

Prophylaxis

Mechanical Ventilation Protocol

Inclusion Criteria

  • PaO2 <= 300 ( corrected for altitude)
  • Bilateral (patchy, diffuse or homogenous) infiltrates consistent with pulmonary edema
  • No clinical evidence of left atrial hypertension

Ventilator Setup

  • Calculate predicted body weight. It is calculated using the formula
Males = 50 + 2.3[height(in inches)-60]
Females = 45.5 + 2.3[height(in inches)-60]
  • Selecting the ventilator mode
  • Set ventilator setings to achieve initial Vt = 8 ml/kg of predicted body weight
  • Reduce VT by 1 ml/kg at intervals ≤ 2 hours until VT = 6ml/kg PBW.
  • Set initial rate to approximate baseline minute ventilation (not > 35 breaths per minute).
  • Adjust VT and RR to achieve pH and plateau pressure goals below.

Oxygenation Goal

  • PaO2 55-80 mmHg or SpO2 88-95% is the goal.
  • Use a minimum PEEP of 5 cm H2O.
  • Consider use of incremental FiO2/PEEP combinations to achieve goal.
Lower PEEP/higher FiO2
FiO2 0.3 0.4 0.4 0.5 0.5 0.6 0.7 0.7 0.7 0.8 0.9 0.9 0.9 1.0
PEEP 5 5 8 8 10 10 10 12 14 14 14 16 18 18-24
Higher PEEP/lower FiO2
FiO2 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.5 0.5 0.5 - 0.8 0.8 0.9 1.0 1.0
PEEP 5 8 10 12 14 14 16 16 18 20 22 22 22 24

Plateau Pressure Goal

  • Plateau pressure goal(Pplat) is <= 30 cm H2O
  • Check Pplat every 4th hourly after change in PEEP ot VT
  • If Pplat > 30 cm of H2O
Decrease VT by 1ml/kg
  • If Pplat < 25 cm of H2O and VT < 6ml/kg
Increase VT by 1ml/kg unbtil Pplat > 25 cm H2O or VT = 6 ml/kg
  • If Pplat < 30 cm and breath stacking or dys-synchrony occurs
Increase VT in 1 ml/kg increments to 7 or 8 ml/kg, if Pplat remains <=30 cm of H2O

PH Goal

  • pH should be maintained at 7.30 - 7.45
  • If pH is less than 7.30 (acidosis)

a. Range of 7.15 - 7.30

Increase respiratory rate until pH > 7.30 or PaCO2
Maximum rate can be 35

b. Less than 7.15

Increase respiratory rate to 35
VT can be increased in 1 ml/kg until pH >7.15 (Pplat target of 30 may be exceeded)
Bicarbonate can be given
Decrease the ventilation rate if possible

I:E Ratio Goal

Recommend that duration of inspiration be less than equal to duration of expiration.

Modification of settings

In adults when 100% FiO2 is used initially, it is easy to calculate the next FiO2 to be used and easy to estimate the shunt fraction. The estimated shunt fraction refers to the amount of oxygen not being absorbed into the circulation. In normal physiology, gas exchange (oxygen/carbon dioxide) occurs at the level of the alveoli in the lungs. The existence of a shunt refers to any process that hinders this gas exchange, leading to wasted oxygen inspired and the flow of unoxygenated blood back to the left heart (which ultimately supplies the rest of the body with unoxygenated blood).

When using 100% FiO2, the degree of shunting is estimated by subtracting the measured PaO2 (from an arterial blood gas) from 700 mmHg. For each difference of 100 mmHg, the shunt is 5%. A shunt of more than 25% should prompt a search for the cause of this hypoxemia, such as mainstem intubation or pneumothorax, and should be treated accordingly. If such complications are not present, other causes must be sought after, and PEEP should be used to treat this intrapulmonary shunt. Other such causes of a shunt include:

When to Withdraw Mechanical Ventilation

Withdrawal from mechanical ventilation --- also known as weaning --- should not be delayed unnecessarily, nor should it be done prematurely. Patients should have their ventilation considered for withdrawal if they are able to support their own ventilation and oxygenation, and this should be assessed continuously. There are several objective parameters to look for when considering withdrawal, but there isn't a specific criteria that generalizes to all patients.

Non-invasive ventilation (Non-invasive Positive Pressure Ventilation or NIPPV)

This refers to all modalities that assist ventilation without the use of an endotracheal tube. Non-invasive ventilation is primarily aimed at minimizing patient discomfort and the complications associated with invasive ventilation. It is often used in cardiac disease, exacerbations of chronic pulmonary disease, sleep apnea, and neuromuscular diseases. Non-invasive ventilation refers only to the patient interface and not the mode of ventilation used; modes may include spontanteous or control modes and may be either pressure or volume modes.

Some commonly used modes of NIPPV include:

  • Continuous positive airway pressure (CPAP).
  • Bi-level Positive Airway Pressure (BIPAP). Pressures alternate between Inspiratory Positive Airway Pressure (IPAP) and a lower Expiratory Positive Airway Pressure (EPAP), triggered by patient effort. On many such devices, backup rates may be set, which deliver IPAP pressures even if patients fail to initiate a breath.
  • Intermittent positive pressure ventilation (IPPV) via mouthpiece or mask

Connection to ventilators

There are various procedures and mechanical devices that provide protection against airway collapse, air leakage, and aspiration:

  • Face mask - In resuscitation and for minor procedures under anesthesia, a face mask is often sufficient to achieve a seal against air leakage. Airway patency of the unconscious patient is maintained either by manipulation of the jaw or by the use of nasopharyngeal or oropharyngeal airway. These are designed to provide a passage of air to the pharynx through the nose or mouth, respectively. Poorly fitted masks often cause nasal bridge ulcers which is a problem for some patients. Face masks are also used for non-invasive ventilation in conscious patients. A face mask does not, however, provide protection against aspiration.
  • Laryngeal mask airway - The laryngeal mask airway (LMA), causes less pain and coughing than a tracheal tube. However, unlike tracheal tubes it does not seal against aspiration, making careful individualised evaluation and patient selection mandatory.
  • Tracheal intubation is often performed for mechanical ventilation of hours to weeks duration. A tube is inserted through the nose (nasotracheal intubation) or mouth (orotracheal intubation) and advanced into the trachea. In most cases tubes with inflatable cuffs are used for protection against leakage and aspiration. Intubation with a cuffed tube is thought to provide the best protection against aspiration. Tracheal tubes inevitably cause pain and coughing. Therefore, unless a patient is unconscious or anesthetized for other reasons, sedative drugs are usually given to provide tolerance of the tube. Other disadvantages of tracheal intubation include damage to the mucosal lining of the nasopharynx or oropharynx and subglottic stenosis.
  • Esophageal obturator airway - commonly used by emergency medical technicians, if they are not authorized to intubate (the "esophageal airway" familiar to fans of the television series, Emergency!). It is a tube which is inserted into the esophagus, past the epiglottis. Once it is inserted, a bladder at the tip of the airway is inflated, to block ("obturate") the esophagus, and air or oxygen is delivered through a series of holes in the side of the tube.
  • Cricothyrotomy - Patients who require emergency airway management, in whom tracheal intubation has been unsuccessful, may require an airway inserted through a surgical opening in the cricothyroid membrane. This is similar to a tracheostomy but a cricothyrotomy is reserved for emergency access. [2]
  • Tracheostomy - When patients require mechanical ventilation for several weeks a tracheostomy may provide the most suitable access to the patient's trachea. A tracheostomy is a surgically created passage into the trachea. Tracheostomy tubes are well tolerated and often do not necessitate any use of sedative drugs. Tracheostomy tubes may be inserted early during treatment in patients with pre-existing severe respiratory disease, or in any patient who are expected to be difficult to wean from mechanical ventilation, i.e., patients who have little muscular reserve.

Terminology

Terminology used in the field of mechanical ventilation and respiratory support:

  • ASB Assisted Spontaneous Breathing -- , also ASV = Assisted Spontaneous Ventilation
  • ASV Adaptive Support Ventilation -- closed-loop mechanical respiration, a further development of MMV
  • PSV Pressure Support Ventilation -- supported spontaneous respiration, see also ASB
  • APRV Airway Pressure Release Ventilation


  • BIPAP Biphasic Positive Airway Pressure
  • TNI Therapy with Nasal Insufflation -- nasal High-Flow mechanical ventialtion for respiration support


  • CPAP Continuous Positive Airway Pressure
  • CPPV Continuous Positive Pressure Ventilation


  • EPAP Expiratory Positive Airway Pressure


  • CMV Continuous Mandatory Ventilation
  • PCMV (P-CMV) Pressure Controlled Mandatory Ventilation
  • VCMV (V-CMV) Volume Controlled Mandatory Ventilation


  • PC Pressure Control -- pressure controlled, fully mechanical ventilation
  • PCV Pressure Controlled Ventilation -- pressure controlled, fully mechanical ventilation


  • VCV Volume Controlled Ventilation -- volume controlled, fully mechanical ventilation
  • S-CPPV Synchronized Continuous Positive Pressure Ventilation


  • HFV High Frequency Ventilation
    • HFPPV High Frequency Positive Pressure Ventilation
    • HFOV High Frequency Oscillatory Ventilation
    • HFJV High Frequency Jet Ventilation
    • HFFI High Frequency Flow Interruption


  • LFPPV Low Frequency Positive Pressure Ventilation


  • ILV Independent Lung Ventilation -- separate sides positive pressure ventilation
  • IPAP Inspiratory Positive Airway Pressure


  • IPPV Intermittent Positive Pressure Ventilation
  • S-IPPV Synchronized Intermittent Positive Pressure Ventilation
  • (S)IMV (Synchronized) Intermittent Mandatory Ventilation
  • MMV Mandatory Minute Volume


  • IRV Inversed Ratio Ventilation -- mechanical ventilation with switched respiration phases/time rate
  • PEEP Positive End-Expiratory Pressure
  • PNPV Positive Negative Pressure Ventilation -- switching pressure mechanical ventilation
  • ZAP Zero Airway Pressure -- Spontaneous respiration under Atmospheric pressure
  • PPS Proportional Pressure Support
  • ATC Automatic Tube Compensation

[5]

References

  1. Chamberlain D (2003) "Never quite there: A tale of resuscitation medicine" Clinical Medicine, Journal of the Royal College of Physicians' 3 6:573-577
  2. Shah, MR et al Impact of the pulmonary artery catheter in critically ill patients: meta-analysis of randomized clinical trials. JAMA. 2005 October 5;294(13):1664-70. PMID: 16204666
  3. Vallee F, et al. Stroke output variations calculated by esophageal Doppler is a reliable predictor of fluid response. Intensive Care Med. 2005 Oct;31(10):1388-93. Epub 2005 August 19. PMID: 16132887
  4. Uchino S, et al. Pulmonary artery catheter versus pulse contour analysis: a prospective epidemiological study. Crit Care. 2006 December 14;10(6):R174 [Epub ahead of print] PMID: 17169160