Bioabsorbable stents: Difference between revisions

Jump to navigation Jump to search
No edit summary
Line 2: Line 2:
{{CMG}}, '''Associate Editor(s)-In-Chief''' [[User :Raviteja Reddy Guddeti| Raviteja Reddy Guddeti, M.B.B.S.]]
{{CMG}}, '''Associate Editor(s)-In-Chief''' [[User :Raviteja Reddy Guddeti| Raviteja Reddy Guddeti, M.B.B.S.]]
==Overview==
==Overview==
Bioabsorbable [[stents]] also known as ''the disappearing stents'' are a promising new discovery in the field of [[Interventional Cardiology]].They have been an interesting field of research over the past decade and half and as the name suggests they get absorbed completely over a period of time after their work has been done.The concept of bioabsorbable stents came into existence as there have been some unmet needs by the traditional bare metal [[stents]], such as stent [[thrombosis]],no drug platform,interfering with MRI-CT imaging,life long presence of implant and not facilitating reintervention.<br>
Bioabsorbable [[stents]] also known as ''the disappearing stents'' are a promising new discovery in the field of [[Interventional Cardiology]].They have been an interesting field of research over the past decade and half and as the name suggests they get absorbed completely over a period of time after their work has been done.The concept of bioabsorbable stents came into existence as there have been some unmet needs by the traditional bare metal [[stents]], such as stent [[thrombosis]],no drug platform,interfering with MRI-CT imaging,life long presence of implant and not facilitating reintervention.<ref>http://www.theheart.org/documents/satellite_programs/intervcardiology/842901/transcript.pdf</ref>


==Types==
==Types==
Line 12: Line 12:


Polymers have been widely used in Cardiovascular devices and are now primarily used as delivery vehicles for drug coatings. Among the polymers suggested for bioabsorbable stents are Poly-L-Lactic acid(PLLA), polyglycolic acid(PGA),Poly(D,L-lactide/glycolide) copolymer(PDLA) and polycaprolactone. The use of bioabsorbable polymer coating reduces the need for extended dual anti-platelet therapy and in turn late thrombotic events. Among the polymers, Poly-L-Lactic acid is widely used in medicine. It breaks down to lactic acid a natural metabolite in human body.
Polymers have been widely used in Cardiovascular devices and are now primarily used as delivery vehicles for drug coatings. Among the polymers suggested for bioabsorbable stents are Poly-L-Lactic acid(PLLA), polyglycolic acid(PGA),Poly(D,L-lactide/glycolide) copolymer(PDLA) and polycaprolactone. The use of bioabsorbable polymer coating reduces the need for extended dual anti-platelet therapy and in turn late thrombotic events. Among the polymers, Poly-L-Lactic acid is widely used in medicine. It breaks down to lactic acid a natural metabolite in human body.
So far two bioabsorbable metals alloys have been proposed for this application: magnesium and iron.The factors that determine the biocompatibility of these alloys are their solubility and their released degradation products. Magnesium stents are made of 93% magnesium and 7% rare-earth-metals. Magnesium was chosen because it is an essential element in the body. The alloy induces rapid endothelialization, has low thrombogenicity and has a degradation time of 2-3 months. It also has calcium antagonist and antiarrhythmic properties and is also not associated with any adverse reactions.
 
So far two bioabsorbable metals alloys have been proposed for this application: magnesium and iron.The factors that determine the biocompatibility of these alloys are their solubility and their released degradation products. Magnesium stents are made of 93% magnesium and 7% rare-earth-metals. Magnesium was chosen because it is an essential element in the body. The alloy induces rapid endothelialization, has low thrombogenicity and has a degradation time of 2-3 months. It has calcium antagonist and antiarrhythmic properties and is also not associated with any adverse reactions.


The following is the list of some of the bioabsorbable stents that are currently under trials.
The following is the list of some of the bioabsorbable stents that are currently under trials.
Line 33: Line 34:
* The '''PROGRESS-AMS study''' is a prospective multicenter non-randomized study that used the Magnesium-alloy stent and was conducted in 63 patients. The results of this study are 100% device and procedural success rate and the study met it's primary endpoint of MACE(major adverse cardiac events) of <30%.
* The '''PROGRESS-AMS study''' is a prospective multicenter non-randomized study that used the Magnesium-alloy stent and was conducted in 63 patients. The results of this study are 100% device and procedural success rate and the study met it's primary endpoint of MACE(major adverse cardiac events) of <30%.
* The '''ABSORB trial''' involving Abbott's drug eluting BVS stent is a prospective non-randomized two phase study in 131 patients. The results demonstrated that the stent successfully treated coronary artery disease([[CAD]]) and was resorbed into the walls of treated arteries after approximately 2 years. There were no blood clots experienced by the patients and no new MACE between 6 months and 4 years ( 3.4% at 4 years)
* The '''ABSORB trial''' involving Abbott's drug eluting BVS stent is a prospective non-randomized two phase study in 131 patients. The results demonstrated that the stent successfully treated coronary artery disease([[CAD]]) and was resorbed into the walls of treated arteries after approximately 2 years. There were no blood clots experienced by the patients and no new MACE between 6 months and 4 years ( 3.4% at 4 years)
* In the '''EVOLVE trial''' experts compared 2 bioabsorbable polymer SYNERGY stents - one deliverig full dose of [[everolimus]] and one delivering half dose of the drug with the durable PROMUS ELEMENT metal stent delivering full dose of the drug in 291 patients. The angigraphic outcomes of the study suggest that it may be possible to achieve at least comparable efficacy with a lower dose of everolimus than is used in commercialy available everolimus-eluting stents.
* In the '''EVOLVE trial''' experts compared 2 bioabsorbable polymer SYNERGY stents - one deliverig full dose of [[everolimus]] and one delivering half dose of the drug with the durable PROMUS ELEMENT metal stent delivering full dose of the drug in 291 patients. The angigraphic outcomes of the study suggest that it may be possible to achieve at least comparable efficacy with a lower dose of everolimus than is used in commercialy available everolimus-eluting stents.<ref> http://www.medpagetoday.com/Cardiology/PCI/31195</ref>


==Advantages==
==Advantages==
Line 53: Line 54:
* These stents are radiolucent which may impair accurate positioning.
* These stents are radiolucent which may impair accurate positioning.
* The polymer alone has limited mechanical performance and a recoil rate of approximately 20%,which requires thick struts that impede their profile and delivery capabilities, especially in small vessels.   
* The polymer alone has limited mechanical performance and a recoil rate of approximately 20%,which requires thick struts that impede their profile and delivery capabilities, especially in small vessels.   
* Some experts opine that these stents can not be used in calcified lesions due to their lack of mechanical strength.
* Some experts opine that these stents can not be used in calcified lesions due to their lack of mechanical strength.<ref>http://www.theheart.org/article/1144463.do</ref>


==References==
==References==
<ref name="pmid22341736">{{cite journal |author=Meredith IT, Verheye S, Dubois CL, ''et al.'' |title=Primary Endpoint Results of the EVOLVE Trial: A Randomized Evaluation of a Novel Bioabsorbable Polymer-Coated, Everolimus-Eluting Coronary Stent |journal=J. Am. Coll. Cardiol. |volume=59 |issue=15 |pages=1362–70 |year=2012 |month=April |pmid=22341736 |doi=10.1016/j.jacc.2011.12.016 |url=}}</ref>
<ref> http://www.medscape.com/viewarticle/523241_2</ref>
{{reflist|2}}
{{reflist|2}}



Revision as of 18:02, 20 April 2012

WikiDoc Resources for Bioabsorbable stents

Articles

Most recent articles on Bioabsorbable stents

Most cited articles on Bioabsorbable stents

Review articles on Bioabsorbable stents

Articles on Bioabsorbable stents in N Eng J Med, Lancet, BMJ

Media

Powerpoint slides on Bioabsorbable stents

Images of Bioabsorbable stents

Photos of Bioabsorbable stents

Podcasts & MP3s on Bioabsorbable stents

Videos on Bioabsorbable stents

Evidence Based Medicine

Cochrane Collaboration on Bioabsorbable stents

Bandolier on Bioabsorbable stents

TRIP on Bioabsorbable stents

Clinical Trials

Ongoing Trials on Bioabsorbable stents at Clinical Trials.gov

Trial results on Bioabsorbable stents

Clinical Trials on Bioabsorbable stents at Google

Guidelines / Policies / Govt

US National Guidelines Clearinghouse on Bioabsorbable stents

NICE Guidance on Bioabsorbable stents

NHS PRODIGY Guidance

FDA on Bioabsorbable stents

CDC on Bioabsorbable stents

Books

Books on Bioabsorbable stents

News

Bioabsorbable stents in the news

Be alerted to news on Bioabsorbable stents

News trends on Bioabsorbable stents

Commentary

Blogs on Bioabsorbable stents

Definitions

Definitions of Bioabsorbable stents

Patient Resources / Community

Patient resources on Bioabsorbable stents

Discussion groups on Bioabsorbable stents

Patient Handouts on Bioabsorbable stents

Directions to Hospitals Treating Bioabsorbable stents

Risk calculators and risk factors for Bioabsorbable stents

Healthcare Provider Resources

Symptoms of Bioabsorbable stents

Causes & Risk Factors for Bioabsorbable stents

Diagnostic studies for Bioabsorbable stents

Treatment of Bioabsorbable stents

Continuing Medical Education (CME)

CME Programs on Bioabsorbable stents

International

Bioabsorbable stents en Espanol

Bioabsorbable stents en Francais

Business

Bioabsorbable stents in the Marketplace

Patents on Bioabsorbable stents

Experimental / Informatics

List of terms related to Bioabsorbable stents

Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1], Associate Editor(s)-In-Chief Raviteja Reddy Guddeti, M.B.B.S.

Overview

Bioabsorbable stents also known as the disappearing stents are a promising new discovery in the field of Interventional Cardiology.They have been an interesting field of research over the past decade and half and as the name suggests they get absorbed completely over a period of time after their work has been done.The concept of bioabsorbable stents came into existence as there have been some unmet needs by the traditional bare metal stents, such as stent thrombosis,no drug platform,interfering with MRI-CT imaging,life long presence of implant and not facilitating reintervention.[1]

Types

Bioabsorbable stents can be broadly classified as two types - Polymeric and metallic types. The key features to be considered while selecting a polymer or an alloy for a bioabsorbable stent are:

  • Strength - to avoid potential immediate recoil
  • Rate of degradation and corrosion
  • Biocompatibility with the vessel wall
  • Lack of toxicity

Polymers have been widely used in Cardiovascular devices and are now primarily used as delivery vehicles for drug coatings. Among the polymers suggested for bioabsorbable stents are Poly-L-Lactic acid(PLLA), polyglycolic acid(PGA),Poly(D,L-lactide/glycolide) copolymer(PDLA) and polycaprolactone. The use of bioabsorbable polymer coating reduces the need for extended dual anti-platelet therapy and in turn late thrombotic events. Among the polymers, Poly-L-Lactic acid is widely used in medicine. It breaks down to lactic acid a natural metabolite in human body.

So far two bioabsorbable metals alloys have been proposed for this application: magnesium and iron.The factors that determine the biocompatibility of these alloys are their solubility and their released degradation products. Magnesium stents are made of 93% magnesium and 7% rare-earth-metals. Magnesium was chosen because it is an essential element in the body. The alloy induces rapid endothelialization, has low thrombogenicity and has a degradation time of 2-3 months. It has calcium antagonist and antiarrhythmic properties and is also not associated with any adverse reactions.

The following is the list of some of the bioabsorbable stents that are currently under trials.

Company Polymer Features
Igaki Medicals Poly-L-Lactic acid Contains no drug, self expanding
REVA Medical Poly(DTE carbonate) with Iodine on the backbone Slide and lock design, paclitaxel drug eluting stent
Biotronic Magnesium-alloy Pimecrolimus drug eluting stent,Balloon expanding
Abbott Vascular Poly-L-Lactic acid Everolimus drug eluting stent,self expanding
  • The Igaki-Tamai stent was one of the first bioabsorbable stents to be tested in clinical trials and is no longer in development now.
  • Bioabsorbable therapeutics and REVA medical are testing stents coated with sirolimus and paclitaxel respectively.
  • The PROGRESS-AMS study is a prospective multicenter non-randomized study that used the Magnesium-alloy stent and was conducted in 63 patients. The results of this study are 100% device and procedural success rate and the study met it's primary endpoint of MACE(major adverse cardiac events) of <30%.
  • The ABSORB trial involving Abbott's drug eluting BVS stent is a prospective non-randomized two phase study in 131 patients. The results demonstrated that the stent successfully treated coronary artery disease(CAD) and was resorbed into the walls of treated arteries after approximately 2 years. There were no blood clots experienced by the patients and no new MACE between 6 months and 4 years ( 3.4% at 4 years)
  • In the EVOLVE trial experts compared 2 bioabsorbable polymer SYNERGY stents - one deliverig full dose of everolimus and one delivering half dose of the drug with the durable PROMUS ELEMENT metal stent delivering full dose of the drug in 291 patients. The angigraphic outcomes of the study suggest that it may be possible to achieve at least comparable efficacy with a lower dose of everolimus than is used in commercialy available everolimus-eluting stents.[2]

Advantages

The main advantages these Bioabsorbable stents can offer over the traditional bare metal stents are:

  • No late stent thrombosis - the stent being absorbed completely leaves behind no stimulus to ignite a chronic inflammatory process and thus in turn reducing the rate of late stent thrombosis which is a major concern of the traditional stents.
  • Short duration of post-stenting use of dual anti-platelet drugs.
  • Obviates metal implants in vessels, leaves only healed natural vessel
  • Facilitates reintervention (PCI and CABG)
  • Prevents the constrictive vascular remodeling postdilatation due to the scaffolding effect of the stent and after being absorbed completely allows late expansive luminal and vessel remodeling.
  • Increased drug loading capabilities that will enable chronic drug release strategies.
  • In the long run, eliminates mechanical stent deformity and strut fractures
  • Can be used in peripheral arteries like that of the tibial artery,femoral artery etc.
  • It's feasible to transfer genes that code key regulatory pathway inside the cells of the arterial wall using polymer stents as vehicles.

Limitations

The bioabsorbable polymer stents have quite a few limitations in their own way:

  • Strength is lower when compared to metallic counterparts, which can result in early recoil post implantation.
  • Associated with a significant degree of local inflammation.
  • These stents are radiolucent which may impair accurate positioning.
  • The polymer alone has limited mechanical performance and a recoil rate of approximately 20%,which requires thick struts that impede their profile and delivery capabilities, especially in small vessels.
  • Some experts opine that these stents can not be used in calcified lesions due to their lack of mechanical strength.[3]

References

[4] [5]

  1. http://www.theheart.org/documents/satellite_programs/intervcardiology/842901/transcript.pdf
  2. http://www.medpagetoday.com/Cardiology/PCI/31195
  3. http://www.theheart.org/article/1144463.do
  4. Meredith IT, Verheye S, Dubois CL; et al. (2012). "Primary Endpoint Results of the EVOLVE Trial: A Randomized Evaluation of a Novel Bioabsorbable Polymer-Coated, Everolimus-Eluting Coronary Stent". J. Am. Coll. Cardiol. 59 (15): 1362–70. doi:10.1016/j.jacc.2011.12.016. PMID 22341736. Unknown parameter |month= ignored (help)
  5. http://www.medscape.com/viewarticle/523241_2

Template:WH Template:WS