Aortic regurgitation surgery

Revision as of 21:11, 2 February 2012 by Mohammed Sbeih (talk | contribs)
Jump to navigation Jump to search

Aortic Regurgitation Microchapters

Home

Patient Information

Overview

Historical Pesrpective

Pathophysiology

Causes

Stages

Differentiating Aortic Regurgitation from other Diseases

Epidemiology and Demographics

Risk Factors

Natural History, Complications and Prognosis

Diagnosis

History and Symptoms

Physical Examination

Cardiac Stress Test

Electrocardiogram

Chest X Ray

Echocardiography

Cardiac MRI

Treatment

Acute Aortic regurgitation

Medical Therapy
Surgery

Chronic Aortic regurgitation

Medical Therapy
Surgery

Precautions and Prophylaxis

Special Scenarios

Pregnancy
Elderly
Young Adults
End-stage Renal Disease

Case Studies

Case #1

Aortic regurgitation surgery On the Web

Most recent articles

Most cited articles

Review articles

CME Programs

Powerpoint slides

Images

American Roentgen Ray Society Images of Aortic regurgitation surgery

All Images
X-rays
Echo & Ultrasound
CT Images
MRI

Ongoing Trials at Clinical Trials.gov

US National Guidelines Clearinghouse

NICE Guidance

FDA on Aortic regurgitation surgery

CDC on Aortic regurgitation surgery

Aortic regurgitation surgery in the news

Blogs on Aortic regurgitation surgery

Directions to Hospitals Treating Aortic regurgitation

Risk calculators and risk factors for Aortic regurgitation surgery

For the WikiPatient page for this topic, click here; For the main page of aortic insufficiency, click here

Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]; Associate Editor-In-Chief: Cafer Zorkun, M.D., Ph.D. [2], Varun Kumar, M.B.B.S., Lakshmi Gopalakrishnan, M.B.B.S., Mohammed A. Sbeih, M.D.[3]

Related Key Words and Synonyms: Aortic valve replacement.

Overview

Indications

Preoperative Evaluation

Procedure

Recovery

Outcomes & Prognosis

Outcomes and Prognosis

Most valve surgery operations are successful. In some rare cases, a valve repair may fail and another operation may be needed. The risk of death or serious complications from isolated aortic valve replacement is typically quoted as being between 1-3% of cases, depending on the health and age of the patient, as well as the skill of the surgeon and the health care institute. The patient's past history of heart surgery affects the mortality rate as well. Patient with mechanical valve may hear a quiet clicking sound in his chest. This is just the sound of the new valve opening and closing, and a sign that the new valve is working.

Mechanical Versus Biological Valves

Mechanical heart valves do not fail often. They last from 12 to 20 years. However, blood clots develop on them. If a blood clot forms, the patient may have a stroke. Bleeding can occur, but this is rare. Biological valves tend to fail over time [1][2], but they have a lower risk of blood clots. Patients with a biological valve may need to have the valve replaced in 10 to 15 years. Patients with a mechanical valve will need to take a blood-thinning medicine for the rest of their lives.

Complications

Complications

Risks of any surgery

  • Blood clots in the legs that may travel to the lungs.
  • Blood loss.
  • Breathing problems.
  • Infection, including in the lungs, kidneys, bladder, chest, or heart valves.
  • Reactions to medicines.
  • Nausea and vomiting.
  • Abnormal or painful scar formation.
  • Allergic skin reaction

Possible risks from having open-heart surgery

  • Heart attack or stroke.
  • Heart rhythm problems; such as atrial fibrillation.
  • Infection in the cut, which is more likely to happen in people who are obese, have diabetes, or have already had this surgery.
  • Memory loss and loss of mental clarity, or "fuzzy thinking."
  • Post-pericardiotomy syndrome, which is a low-grade fever and chest pain. This could last for up to 6 months.

Prosthetic heart valves are associated with a variety of complications

Videos

Videos

Severe aortic insufficiency in patient after aortic valve replacement 1

{{#ev:googlevideo|-3829359717394053857}}

Severe aortic insufficiency in patient after aortic valve replacement 2

{{#ev:googlevideo|-1139143783733805104}}

Severe aortic insufficiency in patient after aortic valve replacement 3

{{#ev:googlevideo|-7501177211861270942}}

Severe aortic insufficiency in patient after aortic valve replacement 4

{{#ev:googlevideo|-4027195456056520519}}

Severe aortic insufficiency in patient after aortic valve replacement 5

{{#ev:googlevideo|3983126063629833286}}

Severe aortic insufficiency in patient after aortic valve replacement 6

{{#ev:googlevideo|5313961274473108141}}

Severe aortic insufficiency in patient after aortic valve replacement 7

{{#ev:googlevideo|-1049019986268408841}}

Severe aortic insufficiency in patient after aortic valve replacement 8

{{#ev:googlevideo|1577454681656420080}}

References

  1. Hammermeister KE, Sethi GK, Henderson WG, Oprian C, Kim T, Rahimtoola S (1993). "A comparison of outcomes in men 11 years after heart-valve replacement with a mechanical valve or bioprosthesis. Veterans Affairs Cooperative Study on Valvular Heart Disease". N Engl J Med. 328 (18): 1289–96. doi:10.1056/NEJM199305063281801. PMID 8469251.
  2. Hammermeister K, Sethi GK, Henderson WG, Grover FL, Oprian C, Rahimtoola SH (2000). "Outcomes 15 years after valve replacement with a mechanical versus a bioprosthetic valve: final report of the Veterans Affairs randomized trial". J Am Coll Cardiol. 36 (4): 1152–8. PMID 11028464.

Template:WH Template:WS