End-diastolic volume
You don't need to be Editor-In-Chief to add or edit content to WikiDoc. You can begin to add to or edit text on this WikiDoc page by clicking on the edit button at the top of this page. Next enter or edit the information that you would like to appear here. Once you are done editing, scroll down and click the Save page button at the bottom of the page.
| Cardiology Network |
| Discuss End-diastolic volume further in the WikiDoc Cardiology Network |
| Adult Congenital |
|---|
| Biomarkers |
| Cardiac Rehabilitation |
| Congestive Heart Failure |
| CT Angiography |
| Echocardiography |
| Electrophysiology |
| Cardiology General |
| Genetics |
| Health Economics |
| Hypertension |
| Interventional Cardiology |
| MRI |
| Nuclear Cardiology |
| Peripheral Arterial Disease |
| Prevention |
| Public Policy |
| Pulmonary Embolism |
| Stable Angina |
| Valvular Heart Disease |
| Vascular Medicine |
Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1] Phone:617-525-6884
Please Take Over This Page and Apply to be Editor-In-Chief for this topic: There can be one or more than one Editor-In-Chief. You may also apply to be an Associate Editor-In-Chief of one of the subtopics below. Please mail us [2] to indicate your interest in serving either as an Editor-In-Chief of the entire topic or as an Associate Editor-In-Chief for a subtopic. Please be sure to attach your CV and or biographical sketch.
In cardiovascular physiology, end-diastolic volume (EDV) is the volume of blood in a ventricle at the end of filling (diastole). Because greater EDVs cause greater distention of the ventricle, EDV is often used synonymously with preload, which refers to the length of the sarcomeres in cardiac muscle prior to contraction (systole). An increase in EDV increases the preload on the heart and, through the Frank-Starling mechanism of the heart, increases the amount of blood ejected from the ventricle during systole (stroke volume).
Because nearly two-thirds of the blood in the systemic circulation is stored in the venous system, end-diastolic volume is closely related to venous compliance. Increasing venous compliance elevates the capacitance of the veins, reducing venous return and therefore end-diastolic volume. Decreasing venous compliance has the opposite effect. For example, activation of the baroreceptor reflex (occurring, for instance, in acute hemorrhage) causes venoconstriction, which decreases venous compliance, improves venous return, and therefore increases end-diastolic volume.
See also
Cardiovascular system, physiology: cardiovascular physiology | |
|---|---|
| Volumes | Preload - Afterload - End-systolic volume - End-diastolic volume - Frank-Starling law of the heart |
| Interactions | Cardiac output - Wiggers diagram - Pressure volume diagram |
| Tropism | Chronotropic - Dromotropic - Inotropic |
| Hemodynamics | Baroreflex - Kinin-kallikrein system - Renin-angiotensin system - Vasoconstrictors - Vasodilators - Compliance - Vascular resistance |
| Other | Electrical conduction system of the heart (Cardiac action potential) |
Acknowledgement and Attribution Regarding Sources of Content
Some of the initial content on this page may be incorporated in part from copyleft sources in the public domain including wikis such as Wikipedia and AskDrWiki. Drug information for patients came from the The National Library of Medicine. Infectious disease information may have come from the Centers for Disease Control (CDC). Differential Diagnoses are drawn from clinicians as well as an amalgamation of 3 sources: 1.The Disease Database; 2. Kahan, Scott, Smith, Ellen G. In A Page: Signs and Symptoms. Malden, Massachusetts: Blackwell Publishing, 2004:3; 3. Sailer, Christian, Wasner, Susanne. Differential Diagnosis Pocket. Hermosa Beach, CA: Borm Bruckmeir Publishing LLC, 2002:7 .

